Cummins fault code · Crankcase and ventilation

Cummins fault code 1844

Crankcase Pressure Circuit: circuit voltage low / shorted low

J1939 SPN101
FMI4
LampAmber warning lamp
SystemCrankcase and ventilation

What it means

Cummins' description: Crankcase Pressure Circuit - Voltage below normal, or shorted to low source.

SPN 101 is Engine Crankcase Pressure. FMI 4 means the voltage on the circuit is lower than possible for a good sensor, usually a short to ground, a damaged harness, or a failed sensor.

The crankcase ventilation system relieves pressure from blow-by gases. The ECM monitors crankcase pressure, and some systems have a heated breather to keep it from freezing.

What the lamp means

An amber (yellow) warning lamp means the engine can usually keep running, but the fault should be repaired soon, ideally the same day.

How serious is it?

Green, yellow, red: three ways this can look

The same code can be a quick fix or a reason to shut down. Match your situation to the closest example.

Green

Keep an eye on it

A one-time crankcase code in freezing weather that cleared once warm.

Yellow

Schedule a repair

The code keeps returning or oil is seeping from seals. Service the breather soon.

Red

Stop and get help

Oil blowing out of the dipstick tube, heavy blow-by smoke, or a stop lamp. Shut it down. High crankcase pressure can mean serious internal wear.

Common causes

FMI 4 is an electrical or signal fault, so start with the circuit:

  • Crankcase pressure sensor failed or wiring fault
  • Breather heater circuit fault

If the circuit checks out, the reading may be real. Other possibilities: plugged crankcase breather or filter; frozen breather in cold weather; disconnected ventilation hose.

What you can check before calling

  • Check that the breather hose is connected and not kinked or frozen
  • Look for oil being pushed out of the dipstick tube or seals
  • Note heavy smoke from the breather tube

Clearing the code without fixing the cause usually brings it right back, and on emissions systems it can restart derate timers.

Engines and sources

Listed by Cummins for: QSB 6.7, QSL 9, QSX 15, QSB 4.5, QSG 12. Cummins uses the same fault code numbers across its electronic engines, including on-highway models like the ISB/B6.7, ISL/L9 and ISX/X15, though not every code applies to every engine or software level. Source: Cummins Tier 4 Fault Codes. Always confirm with Cummins service information (QuickServe) for your engine serial number.

Look up another code

Cummins fault code (like 1922), J1939 SPN and FMI (like SPN 3251 FMI 0), or an OBD-II code (like P0420).

Questions

What does Cummins fault code 1844 mean?

Cummins fault code 1844 is J1939 SPN 101 FMI 4: Crankcase Pressure Circuit - Voltage below normal, or shorted to low source. In plain terms: crankcase pressure circuit: circuit voltage low / shorted low.

Can I keep driving with Cummins code 1844?

Usually for a short time, if the engine runs normally and no other warnings are on. Get it diagnosed soon, because many amber codes lead to a derate if ignored. Look at the green, yellow and red examples on this page to judge your situation.

What is the SPN and FMI for Cummins code 1844?

SPN 101 identifies the part or system (Engine Crankcase Pressure). FMI 4 describes the type of failure: circuit voltage low / shorted low.

What usually causes Cummins code 1844?

The most common causes are: crankcase pressure sensor failed or wiring fault; breather heater circuit fault.

Diesel down in the Midlands?

We work on Cummins-powered pickups, vans and medium-duty trucks across Lexington, Columbia and the Midlands, on site at your yard or roadside.

CallBook