Cummins fault code lookup. 962 codes.
Look up any Cummins fault code or J1939 SPN and FMI. Plain-English meaning, what the dash lamp means, common causes, and green, yellow and red examples so you know whether to keep driving.
Cummins fault code (like 1922), J1939 SPN and FMI (like SPN 3251 FMI 0), or an OBD-II code (like P0420).
Every code, grouped by what it affects
Lamp colors: red stop, amber warning, no lamp. Codes come from Cummins' published fault code tables.
DPF (diesel particulate filter) 53 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 1879 | 3251 | 3 | DPF Differential Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 1881 | 3251 | 4 | DPF Differential Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 1883 | 3251 | 2 | DPF Differential Pressure Sensor: erratic or intermittent signal | |
| 1921 | 3251 | 16 | DPF Differential Pressure: reading above normal (moderately severe) | |
| 1922 | 3251 | 0 | DPF Differential Pressure: reading above normal (most severe) | |
| 1981 | 3936 | 15 | DPF System: reading above normal (least severe) | |
| 1993 | 4795 | 31 | DPF Missing: condition exists | |
| 2639 | 3251 | 15 | DPF Differential Pressure: reading above normal (least severe) | |
| 2742 | 3249 | 17 | Exhaust Gas Temperature 2: reading below normal (least severe) | |
| 2743 | 3249 | 18 | Exhaust Gas Temperature 2: reading below normal (moderately severe) | |
| 2754 | 81 | 16 | Engine DPF Intake Pressure: reading above normal (moderately severe) | |
| 2777 | 3703 | 31 | Particulate Trap Active Regeneration Inhibited Due to Inhibit Switch: condition exists | |
| 3133 | 3610 | 3 | DPF Outlet Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 3134 | 3610 | 4 | DPF Outlet Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 3135 | 3610 | 2 | DPF Outlet Pressure: erratic or intermittent signal | |
| 3245 | 3936 | 7 | DPF System: not responding / out of adjustment | |
| 3253 | 3242 | 16 | DPF Intake Temperature: reading above normal (moderately severe) | |
| 3254 | 3242 | 15 | DPF Intake Temperature: reading above normal (least severe) | |
| 3255 | 3246 | 16 | DPF Outlet Temperature: reading above normal (moderately severe) | |
| 3256 | 3246 | 15 | DPF Outlet Temperature: reading above normal (least severe) | |
| 3311 | 3242 | 0 | DPF Intake Temperature: reading above normal (most severe) | |
| 3312 | 3246 | 0 | DPF Outlet Temperature: reading above normal (most severe) | |
| 3316 | 3242 | 4 | DPF Intake Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 3317 | 3242 | 3 | DPF Intake Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 3318 | 3242 | 2 | DPF Intake Temperature: erratic or intermittent signal | |
| 3319 | 3246 | 3 | DPF Outlet Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 3321 | 3246 | 4 | DPF Outlet Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 3322 | 3246 | 2 | DPF Outlet Temperature: erratic or intermittent signal | |
| 3375 | 5397 | 31 | DPF Regeneration too Frequent: condition exists | |
| 3376 | 5319 | 31 | DPF Incomplete Regeneration: condition exists | |
| 3396 | 3750 | 31 | DPF 1 Conditions Not Met for Active Regeneration: condition exists | |
| 3753 | 3713 | 31 | DPF Active Regeneration Inhibited Due to System Timeout: condition exists | |
| 4143 | 5741 | 3 | Outlet Soot Sensor: circuit voltage high / shorted high | |
| 4144 | 5741 | 4 | Outlet Soot Sensor: circuit voltage low / shorted low | |
| 4151 | 5742 | 9 | DPF Temperature Sensor Module: abnormal update rate | |
| 4153 | 5747 | 3 | Outlet Soot Sensor Heater: circuit voltage high / shorted high | |
| 4154 | 5747 | 4 | Outlet Soot Sensor Heater: circuit voltage low / shorted low | |
| 4158 | 5742 | 12 | DPF Temperature Sensor Module: bad device or component | |
| 4161 | 5742 | 3 | DPF Temperature Sensor Module: circuit voltage high / shorted high | |
| 4162 | 5742 | 4 | DPF Temperature Sensor Module: circuit voltage low / shorted low | |
| 4163 | 5742 | 16 | DPF Temperature Sensor Module- Data Valid But Above Normal Operating Range: reading above normal (moderately severe) | |
| 4213 | 3695 | 2 | Regeneration Inhibit Switch: erratic or intermittent signal | |
| 4259 | 5742 | 11 | DPF Temperature Sensor Module: root cause not known | |
| 4449 | 5747 | 10 | Outlet Soot Sensor Heater: abnormal rate of change | |
| 4451 | 5741 | 2 | Outlet Soot: erratic or intermittent signal | |
| 4584 | 3936 | 14 | DPF System: special instructions | |
| 5938 | 3750 | 14 | DPF 1 Conditions Not Met for Active Regeneration: special instructions | |
| 6265 | 3936 | 7 | DPF System: not responding / out of adjustment | |
| 6551 | 3610 | 3 | DPF Outlet Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 6552 | 3610 | 4 | DPF Outlet Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 6553 | 3610 | 2 | DPF Outlet Pressure: erratic or intermittent signal | |
| 6568 | 3695 | 2 | Regeneration Inhibit Switch: erratic or intermittent signal | |
| 6596 | 3713 | 31 | DPF Active Regeneration Inhibited Due to System Timeout: condition exists |
DEF (diesel exhaust fluid) system 117 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 1668 | 1761 | 4 | DEF Tank Level Sensor Circuit: circuit voltage low / shorted low | |
| 1669 | 1761 | 3 | DEF Tank Level Sensor Circuit: circuit voltage high / shorted high | |
| 1673 | 1761 | 1 | DEF Tank Level: reading below normal (most severe) | |
| 1677 | 3031 | 4 | DEF Tank Temperature Sensor: circuit voltage low / shorted low | |
| 1678 | 3031 | 3 | DEF Tank Temperature Sensor: circuit voltage high / shorted high | |
| 1679 | 3031 | 2 | DEF Tank Temperature: erratic or intermittent signal | |
| 1682 | 3362 | 31 | DEF Dosing Unit Input Lines: condition exists | |
| 1683 | 3363 | 3 | DEF Tank Heater: circuit voltage high / shorted high | |
| 1684 | 3363 | 4 | DEF Tank Heater: circuit voltage low / shorted low | |
| 1685 | 3364 | 4 | DEF Quality Sensor Circuit: circuit voltage low / shorted low | |
| 1686 | 3364 | 3 | DEF Quality Sensor Circuit: circuit voltage high / shorted high | |
| 1699 | 1761 | 2 | DEF Tank Level Sensor: erratic or intermittent signal | |
| 1712 | 3363 | 18 | DEF Tank Heater: reading below normal (moderately severe) | |
| 1713 | 3363 | 16 | DEF Tank Heater: reading above normal (moderately severe) | |
| 1714 | 3364 | 13 | DEF Quality: out of calibration | |
| 1715 | 3364 | 11 | DEF Quality: root cause not known | |
| 2976 | 3361 | 2 | DEF Dosing Unit Temperature: erratic or intermittent signal | |
| 3237 | 4340 | 3 | DEF Line Heater 1 Circuit: circuit voltage high / shorted high | |
| 3238 | 4340 | 4 | DEF Line Heater 1 Circuit: circuit voltage low / shorted low | |
| 3239 | 4342 | 3 | DEF Line Heater 2 Circuit: circuit voltage high / shorted high | |
| 3241 | 4342 | 4 | DEF Line Heater 2 Circuit: circuit voltage low / shorted low | |
| 3242 | 3363 | 7 | DEF Tank Heater: not responding / out of adjustment | |
| 3258 | 4340 | 5 | DEF Line Heater 1 Circuit: circuit open / current low | |
| 3261 | 4342 | 5 | DEF Line Heater 2 Circuit: circuit open / current low | |
| 3422 | 4344 | 3 | DEF Line Heater 3 Circuit: circuit voltage high / shorted high | |
| 3423 | 4344 | 4 | DEF Line Heater 3 Circuit: circuit voltage low / shorted low | |
| 3425 | 4344 | 5 | DEF Line Heater 3 Circuit: circuit open / current low | |
| 3497 | 1761 | 17 | DEF Tank Level: reading below normal (least severe) | |
| 3498 | 1761 | 18 | DEF Tank Level: reading below normal (moderately severe) | |
| 3558 | 3361 | 3 | DEF Dosing Unit: circuit voltage high / shorted high | |
| 3559 | 3361 | 4 | DEF Dosing Unit: circuit voltage low / shorted low | |
| 3562 | 5491 | 3 | DEF Line Heater Relay: circuit voltage high / shorted high | |
| 3563 | 5491 | 4 | DEF Line Heater Relay: circuit voltage low / shorted low | |
| 3567 | 5394 | 5 | DEF Dosing Valve: circuit open / current low | |
| 3568 | 5394 | 7 | DEF Dosing Valve: not responding / out of adjustment | |
| 3571 | 4334 | 3 | DEF Pressure Sensor: circuit voltage high / shorted high | |
| 3572 | 4334 | 4 | DEF Pressure Sensor: circuit voltage low / shorted low | |
| 3574 | 4334 | 18 | DEF Pressure Sensor: reading below normal (moderately severe) | |
| 3575 | 4334 | 16 | DEF Pressure Sensor: reading above normal (moderately severe) | |
| 3577 | 4376 | 3 | DEF Return Valve: circuit voltage high / shorted high | |
| 3578 | 4376 | 4 | DEF Return Valve: circuit voltage low / shorted low | |
| 3596 | 4334 | 2 | DEF Pressure Sensor: erratic or intermittent signal | |
| 3713 | 5491 | 7 | DEF Line Heater Relay: not responding / out of adjustment | |
| 3755 | 5394 | 2 | DEF Dosing Valve: erratic or intermittent signal | |
| 3866 | 3364 | 1 | DEF Quality: reading below normal (most severe) | |
| 3867 | 3364 | 18 | DEF Quality: reading below normal (moderately severe) | |
| 3868 | 3364 | 9 | DEF Quality: abnormal update rate | |
| 3876 | 3364 | 7 | DEF Quality Sensor: not responding / out of adjustment | |
| 3877 | 3364 | 12 | DEF Quality Sensor: bad device or component | |
| 3878 | 3364 | 2 | DEF Quality: erratic or intermittent signal | |
| 4155 | 5746 | 3 | DEF Dosing Unit Heater Relay: circuit voltage high / shorted high | |
| 4156 | 5746 | 4 | DEF Dosing Unit Heater Relay: circuit voltage low / shorted low | |
| 4157 | 4376 | 7 | DEF Return Valve: not responding / out of adjustment | |
| 4168 | 5745 | 3 | DEF Dosing Unit Heater: circuit voltage high / shorted high | |
| 4169 | 5745 | 4 | DEF Dosing Unit Heater: circuit voltage low / shorted low | |
| 4171 | 5745 | 18 | DEF Dosing Unit Heater: reading below normal (moderately severe) | |
| 4174 | 4337 | 3 | DEF Dosing Temperature Sensor: circuit voltage high / shorted high | |
| 4175 | 4337 | 4 | DEF Dosing Temperature Sensor: circuit voltage low / shorted low | |
| 4233 | 3515 | 3 | DEF Temperature 2 Sensor Circuit: circuit voltage high / shorted high | |
| 4234 | 3515 | 4 | DEF Temperature 2 Sensor Circuit: circuit voltage low / shorted low | |
| 4235 | 3521 | 31 | DEF Property: condition exists | |
| 4242 | 3515 | 2 | DEF Temperature 2: erratic or intermittent signal | |
| 4243 | 3515 | 10 | DEF Temperature 2 Abnormal Rate of Change: abnormal rate of change | |
| 4244 | 4337 | 2 | DEF Dosing Temperature: erratic or intermittent signal | |
| 4245 | 5798 | 2 | DEF Dosing Unit Heater Temperature: erratic or intermittent signal | |
| 4249 | 4337 | 10 | DEF Dosing Temperature: abnormal rate of change | |
| 4251 | 5798 | 10 | DEF Dosing Unit Heater Temperature: abnormal rate of change | |
| 4277 | 3364 | 10 | DEF Quality: abnormal rate of change | |
| 4486 | 5839 | 31 | DEF Consumption Malfunction: condition exists | |
| 4487 | 5840 | 31 | DEF Dosing Malfunction: condition exists | |
| 4488 | 5841 | 31 | DEF Quality Malfunction: condition exists | |
| 4572 | 3031 | 9 | DEF Tank Temperature: abnormal update rate | |
| 4573 | 3826 | 18 | DEF Average Consumption: reading below normal (moderately severe) | |
| 4677 | 1761 | 9 | SAE J1939 Multiplexing PGN Timeout Error: abnormal update rate | |
| 4679 | 1761 | 5 | DEF Tank Level Sensor Circuit: circuit open / current low | |
| 4682 | 3031 | 5 | DEF Tank Temperature Sensor Circuit: circuit open / current low | |
| 4731 | 3031 | 13 | DEF Tank Temperature Sensor: out of calibration | |
| 4732 | 1761 | 13 | DEF Tank Level Sensor: out of calibration | |
| 4736 | 3031 | 6 | DEF Tank Temperature Sensor Circuit: circuit grounded / current high | |
| 4737 | 3031 | 11 | DEF Tank Temperature: root cause not known | |
| 4738 | 1761 | 6 | DEF Tank Level Sensor Circuit: circuit grounded / current high | |
| 4739 | 1761 | 11 | DEF Tank Level Sensor: root cause not known | |
| 4743 | 3515 | 5 | DEF Temperature 2 Sensor Circuit: circuit open / current low | |
| 4744 | 3515 | 6 | DEF Temperature 2 Sensor Circuit: circuit grounded / current high | |
| 4745 | 3515 | 11 | DEF Temperature 2: root cause not known | |
| 4752 | 520716 | 3 | DEF Dosing Valve 1 Heater: circuit voltage high / shorted high | |
| 4753 | 520716 | 4 | DEF Dosing Valve 1 Heater: circuit voltage low / shorted low | |
| 4768 | 3521 | 11 | DEF Property: root cause not known | |
| 4769 | 1761 | 10 | DEF Tank Level Sensor: abnormal rate of change | |
| 4842 | 3364 | 15 | DEF Quality: reading above normal (least severe) | |
| 5278 | 6802 | 31 | DEF Dosing System Frozen: condition exists | |
| 5866 | 520953 | 3 | DEF Dosing Unit Relay Feedback- Voltage Above Normal or Shorted to High Source.: circuit voltage high / shorted high | |
| 5867 | 520953 | 4 | DEF Dosing Unit Relay Feedback- Voltage Below Normal or Shorted to Low Source.: circuit voltage low / shorted low | |
| 6475 | 3363 | 7 | DEF Tank Heater: not responding / out of adjustment | |
| 6476 | 3363 | 18 | DEF Tank Heater: reading below normal (moderately severe) | |
| 6477 | 5491 | 3 | DEF Line Heater Relay: circuit voltage high / shorted high | |
| 6478 | 5491 | 4 | DEF Line Heater Relay: circuit voltage low / shorted low | |
| 6479 | 3363 | 3 | DEF Tank Heater: circuit voltage high / shorted high | |
| 6481 | 3363 | 4 | DEF Tank Heater: circuit voltage low / shorted low | |
| 6482 | 4340 | 5 | DEF Line Heater 1 Circuit: circuit open / current low | |
| 6483 | 4342 | 5 | DEF Line Heater 2 Circuit: circuit open / current low | |
| 6484 | 4344 | 5 | DEF Line Heater 3 Circuit: circuit open / current low | |
| 6513 | 5745 | 17 | DEF Dosing Unit Heater: reading below normal (least severe) | |
| 6526 | 1761 | 13 | DEF Tank Level Sensor: out of calibration | |
| 6527 | 4376 | 7 | DEF Return Valve: not responding / out of adjustment | |
| 6529 | 5746 | 3 | DEF Dosing Unit Heater Relay: circuit voltage high / shorted high | |
| 6531 | 4340 | 3 | DEF Line Heater 1 Circuit: circuit voltage high / shorted high | |
| 6532 | 4340 | 4 | DEF Line Heater 1 Circuit: circuit voltage low / shorted low | |
| 6533 | 4342 | 3 | DEF Line Heater 2 Circuit: circuit voltage high / shorted high | |
| 6534 | 4342 | 4 | DEF Line Heater 2 Circuit: circuit voltage low / shorted low | |
| 6535 | 4344 | 3 | DEF Line Heater 3 Circuit: circuit voltage high / shorted high | |
| 6536 | 4344 | 4 | DEF Line Heater 3 Circuit: circuit voltage low / shorted low | |
| 6537 | 5491 | 7 | DEF Line Heater Relay: not responding / out of adjustment | |
| 6559 | 3031 | 4 | DEF Tank Temperature Sensor: circuit voltage low / shorted low | |
| 6562 | 1761 | 11 | DEF Tank Level Sensor: root cause not known | |
| 6619 | 3515 | 10 | DEF Temperature 2: abnormal rate of change | |
| 6752 | 3364 | 18 | DEF Quality: reading below normal (moderately severe) |
SCR catalyst and inducement 36 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 3142 | 4360 | 3 | SCR Intake Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 3143 | 4360 | 4 | SCR Intake Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 3144 | 4360 | 2 | SCR Intake Temperature Sensor: erratic or intermittent signal | |
| 3146 | 4363 | 3 | SCR Outlet Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 3147 | 4363 | 4 | SCR Outlet Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 3148 | 4363 | 2 | SCR Outlet Temperature Sensor: erratic or intermittent signal | |
| 3151 | 4794 | 31 | SCR Catalyst System Missing: condition exists | |
| 3164 | 4360 | 15 | SCR Intake Temperature: reading above normal (least severe) | |
| 3165 | 4363 | 0 | SCR Outlet Temperature: reading above normal (most severe) | |
| 3229 | 4360 | 0 | SCR Intake Temperature: reading above normal (most severe) | |
| 3231 | 4360 | 16 | SCR Intake Temperature: reading above normal (moderately severe) | |
| 3235 | 4363 | 16 | SCR Outlet Temperature: reading above normal (moderately severe) | |
| 3582 | 4364 | 18 | SCR Catalyst Conversion Efficiency: reading below normal (moderately severe) | |
| 3712 | 5246 | 0 | SCR Operator Inducement: reading above normal (most severe) | |
| 3751 | 4792 | 7 | SCR Catalyst System: not responding / out of adjustment | |
| 4152 | 5743 | 9 | SCR Temperature Sensor Module: abnormal update rate | |
| 4159 | 5743 | 12 | SCR Temperature Sensor Module: bad device or component | |
| 4164 | 5743 | 3 | SCR Temperature Sensor Module: circuit voltage high / shorted high | |
| 4165 | 5743 | 4 | SCR Temperature Sensor Module: circuit voltage low / shorted low | |
| 4166 | 5743 | 16 | SCR Temperature Sensor Module: reading above normal (moderately severe) | |
| 4261 | 5743 | 11 | SCR Temperature Sensor Module: root cause not known | |
| 4489 | 5842 | 31 | SCR Monitoring System Malfunction: condition exists | |
| 4585 | 4792 | 14 | SCR Catalyst System: special instructions | |
| 4586 | 4339 | 31 | SCR Feedback Control Status: condition exists | |
| 4658 | 4331 | 18 | SCR Actual Dosing Reagent Quantity: reading below normal (moderately severe) | |
| 4863 | 5245 | 31 | DEF Tank Low Level Indicator: condition exists | |
| 5247 | 4360 | 16 | SCR Intake Temperature: reading above normal (moderately severe) | |
| 5631 | 6928 | 31 | SCR System Cleaning Inhibited Due to System Timeout: condition exists | |
| 5632 | 6918 | 31 | SCR System Cleaning Inhibited Due to Inhibit Switch: condition exists | |
| 5653 | 6881 | 9 | SCR Operator Inducement Override Switch: abnormal update rate | |
| 5654 | 6881 | 13 | SCR Operator Inducement Override Switch: out of calibration | |
| 6517 | 4364 | 17 | SCR Catalyst Conversion Efficiency: reading below normal (least severe) | |
| 6569 | 4363 | 3 | SCR Outlet Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 6571 | 4363 | 4 | SCR Outlet Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 6597 | 6928 | 31 | SCR System Cleaning Inhibited Due to System Timeout: condition exists | |
| 6634 | 7848 | 14 | SCR System Conditions Not Met for Active Cleaning: special instructions |
NOx sensors 33 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 1694 | 3226 | 2 | Outlet NOx Sensor: erratic or intermittent signal | |
| 1861 | 3217 | 2 | Intake Oxygen Sensor: erratic or intermittent signal | |
| 1885 | 3216 | 4 | Intake NOx Sensor Circuit: circuit voltage low / shorted low | |
| 1887 | 3226 | 4 | Outlet NOx Sensor Circuit: circuit voltage low / shorted low | |
| 2683 | 3227 | 9 | Outlet Oxygen Sensor Circuit: abnormal update rate | |
| 2771 | 3226 | 9 | Outlet NOx Sensor: abnormal update rate | |
| 3228 | 3216 | 2 | Intake NOx Sensor: erratic or intermittent signal | |
| 3232 | 3216 | 9 | Intake NOx Sensor: abnormal update rate | |
| 3543 | 4094 | 31 | NOx limits exceeded due to Insufficient Reagent Quality: condition exists | |
| 3545 | 3226 | 10 | Outlet NOx Sensor: abnormal rate of change | |
| 3547 | 4096 | 31 | DEF Tank Empty: condition exists | |
| 3583 | 5031 | 10 | Outlet NOx Sensor Heater: abnormal rate of change | |
| 3649 | 5024 | 10 | Intake NOx Sensor Heater: abnormal rate of change | |
| 3681 | 3228 | 2 | Outlet NOx Sensor Power Supply: erratic or intermittent signal | |
| 3682 | 3218 | 2 | Intake NOx Sensor Power Supply: erratic or intermittent signal | |
| 3717 | 3226 | 13 | Outlet NOx Sensor: out of calibration | |
| 3718 | 3216 | 13 | Intake NOx: out of calibration | |
| 3725 | 3216 | 10 | Intake NOx Sensor: abnormal rate of change | |
| 3748 | 3216 | 20 | Intake NOx Sensor: data drifted high | |
| 3749 | 3226 | 20 | Outlet NOx Sensor: data drifted high | |
| 3988 | 3265 | 9 | 2 Outlet NOx: abnormal update rate | |
| 4145 | 3255 | 9 | 2 Intake NOx Sensor: abnormal update rate | |
| 4452 | 520668 | 31 | Outlet NOx Sensor Closed Loop Operation: condition exists | |
| 6458 | 3216 | 20 | Intake NOx Sensor: data drifted high | |
| 6459 | 3216 | 21 | Intake NOx Sensor: data drifted low | |
| 6462 | 3226 | 20 | Outlet NOx Sensor: data drifted high | |
| 6463 | 3226 | 21 | Outlet NOx Sensor: data drifted low | |
| 6464 | 3226 | 2 | Outlet NOx Sensor: erratic or intermittent signal | |
| 6521 | 3226 | 4 | Outlet NOx Sensor Circuit- Voltage below normal or shorted to low source: circuit voltage low / shorted low | |
| 6565 | 3226 | 10 | Outlet NOx Sensor: abnormal rate of change | |
| 6581 | 5031 | 10 | Outlet NOx Sensor Heater: abnormal rate of change | |
| 6582 | 3228 | 2 | Outlet NOx Sensor Power Supply: erratic or intermittent signal | |
| 6621 | 3216 | 10 | Intake NOx Sensor: abnormal rate of change |
DOC and aftertreatment fuel doser 52 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 1664 | 4796 | 31 | DOC Missing: condition exists | |
| 1691 | 5298 | 18 | DOC Conversion Efficiency: reading below normal (moderately severe) | |
| 1932 | 3556 | 2 | Doser: erratic or intermittent signal | |
| 1964 | 3556 | 7 | Doser: not responding / out of adjustment | |
| 1977 | 3556 | 5 | Doser Circuit: circuit open / current low | |
| 2637 | 5018 | 11 | DOC Face Plugged: root cause not known | |
| 2638 | 5298 | 17 | DOC Conversion Efficiency: reading below normal (least severe) | |
| 2732 | 4097 | 3 | Fuel Drain Valve Circuit: circuit voltage high / shorted high | |
| 2733 | 4097 | 4 | Fuel Drain Valve Circuit: circuit voltage low / shorted low | |
| 2778 | 3481 | 16 | Fuel Rate: reading above normal (moderately severe) | |
| 2878 | 4097 | 7 | Fuel Drain Valve: not responding / out of adjustment | |
| 3152 | 4809 | 3 | Warm Up DOC Intake Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 3153 | 4809 | 4 | Warm Up DOC Intake Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 3154 | 4809 | 2 | Warm Up DOC Intake Temperature: erratic or intermittent signal | |
| 3155 | 4810 | 3 | Warm Up DOC Outlet Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 3156 | 4810 | 4 | Warm Up DOC Outlet Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 3157 | 4810 | 2 | Warm Up DOC Outlet Temperature: erratic or intermittent signal | |
| 3158 | 4793 | 31 | Warm Up DOC Missing: condition exists | |
| 3162 | 4810 | 0 | Warm Up DOC Outlet Temperature: reading above normal (most severe) | |
| 3166 | 4809 | 13 | Warm Up DOC Intake Temperature Sensor Swapped: out of calibration | |
| 3167 | 3556 | 18 | Doser: reading below normal (moderately severe) | |
| 3169 | 4810 | 16 | Warm Up DOC Outlet Temperature: reading above normal (moderately severe) | |
| 3223 | 3490 | 4 | Purge Air Actuator Circuit: circuit voltage low / shorted low | |
| 3224 | 3490 | 3 | Purge Air Actuator Circuit: circuit voltage high / shorted high | |
| 3225 | 3490 | 7 | Purge Air Actuator: not responding / out of adjustment | |
| 3247 | 4809 | 16 | Warm Up DOC Intake Temperature: reading above normal (moderately severe) | |
| 3249 | 4810 | 15 | Warm Up DOC Outlet Temperature: reading above normal (least severe) | |
| 3251 | 4765 | 16 | DOC Intake Temperature: reading above normal (moderately severe) | |
| 3313 | 4765 | 4 | DOC Intake Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 3314 | 4765 | 3 | DOC Intake Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 3315 | 4765 | 2 | DOC Intake Temperature: erratic or intermittent signal | |
| 3325 | 4765 | 13 | DOC Intake Temperature Swapped: out of calibration | |
| 4253 | 5797 | 12 | Warm Up DOC Temperature Sensor Module: bad device or component | |
| 4254 | 5797 | 3 | Warm Up DOC Temperature Sensor Module: circuit voltage high / shorted high | |
| 4255 | 5797 | 4 | Warm Up DOC Temperature Sensor Module: circuit voltage low / shorted low | |
| 4256 | 5797 | 16 | Warm Up DOC Temperature Sensor Module: reading above normal (moderately severe) | |
| 4258 | 5797 | 11 | Warm Up DOC Temperature Sensor Module: root cause not known | |
| 4533 | 4766 | 3 | DOC Outlet Gas Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 4534 | 4766 | 4 | DOC Outlet Gas Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 5386 | 4766 | 2 | DOC Outlet Gas Temperature: erratic or intermittent signal | |
| 5387 | 4766 | 0 | DOC Outlet Gas Temperature: reading above normal (most severe) | |
| 5388 | 4766 | 16 | DOC Outlet Gas Temperature: reading above normal (moderately severe) | |
| 5389 | 4766 | 15 | DOC Outlet Gas Temperature: reading above normal (least severe) | |
| 5391 | 6882 | 9 | DOC Temperature Sensor Module: abnormal update rate | |
| 5392 | 6882 | 12 | DOC Temperature Sensor Module: bad device or component | |
| 5393 | 6882 | 3 | DOC Temperature Sensor Module: circuit voltage high / shorted high | |
| 5394 | 6882 | 4 | DOC Temperature Sensor Module: circuit voltage low / shorted low | |
| 5395 | 6882 | 11 | DOC Temperature Sensor Module: root cause not known | |
| 5396 | 6882 | 16 | DOC Temperature Sensor Module: reading above normal (moderately severe) | |
| 5617 | 524286 | 31 | DOC System- Special Instruction: condition exists | |
| 6539 | 4765 | 2 | DOC Intake Temperature: erratic or intermittent signal | |
| 6726 | 4796 | 31 | DOC Missing: condition exists |
EGR (exhaust gas recirculation) 21 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 1228 | 27 | 2 | EGR Valve Position: erratic or intermittent signal | |
| 1866 | 411 | 2 | EGR Differential Pressure: erratic or intermittent signal | |
| 1867 | 412 | 2 | EGR Temperature: erratic or intermittent signal | |
| 1893 | 2791 | 9 | EGR Valve Control Circuit: abnormal update rate | |
| 1896 | 2791 | 13 | EGR Valve Controller: out of calibration | |
| 1961 | 2791 | 15 | EGR Valve Control Circuit Over Temperature: reading above normal (least severe) | |
| 2272 | 27 | 4 | EGR Valve Position Circuit: circuit voltage low / shorted low | |
| 2273 | 411 | 3 | EGR Differential Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 2274 | 411 | 4 | EGR Differential Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 2349 | 2791 | 5 | EGR Valve Control Circuit: circuit open / current low | |
| 2353 | 2791 | 6 | EGR Valve Control Circuit: circuit grounded / current high | |
| 2357 | 2791 | 7 | EGR Valve Control Circuit: not responding / out of adjustment | |
| 2375 | 412 | 3 | EGR Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 2376 | 412 | 4 | EGR Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 2961 | 412 | 15 | EGR Temperature: reading above normal (least severe) | |
| 2962 | 412 | 16 | EGR Temperature: reading above normal (moderately severe) | |
| 3136 | 5019 | 3 | Engine EGR Outlet Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 3137 | 5019 | 4 | Engine EGR Outlet Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 3138 | 5019 | 2 | Engine EGR Outlet Pressure: erratic or intermittent signal | |
| 4485 | 5838 | 31 | EGR Valve Malfunction: condition exists | |
| 6555 | 2791 | 7 | EGR Valve Control Circuit: not responding / out of adjustment |
Turbo, VGT and boost 47 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 122 | 102 | 3 | Intake Manifold 1 Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 123 | 102 | 4 | Intake Manifold 1 Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 124 | 102 | 16 | Intake Manifold 1 Pressure: reading above normal (moderately severe) | |
| 125 | 102 | 18 | Intake Manifold 1 Pressure: reading below normal (moderately severe) | |
| 433 | 102 | 2 | Intake Manifold Pressure Sensor Circuit: erratic or intermittent signal | |
| 466 | 1188 | 4 | Turbocharger #1 Wastegate Control Circuit: circuit voltage low / shorted low | |
| 595 | 103 | 16 | Turbocharger 1 Speed: reading above normal (moderately severe) | |
| 616 | 1173 | 16 | High Turbo Compressor Inlet Temp RB: reading above normal (moderately severe) | |
| 617 | 1172 | 0 | High Turbo Compressor Inlet Temp LB: reading above normal (most severe) | |
| 629 | 1176 | 18 | Turbocharger 1 Compressor Intake Pressure: reading below normal (moderately severe) | |
| 686 | 103 | 2 | Turbocharger 1 Speed: erratic or intermittent signal | |
| 687 | 103 | 18 | Turbocharger 1 Speed: reading below normal (moderately severe) | |
| 691 | 1172 | 3 | Turbocharger 1 Compressor Intake Temperature Circuit: circuit voltage high / shorted high | |
| 692 | 1172 | 4 | Turbocharger 1 Compressor Intake Temperature Circuit: circuit voltage low / shorted low | |
| 693 | 1172 | 2 | Turbocharger 1 Compressor Intake Temperature: erratic or intermittent signal | |
| 694 | 1173 | 3 | RBF Turbo Comp Inlet Temp Sens Failed High: circuit voltage high / shorted high | |
| 695 | 1174 | 4 | RBR Turbo Comp Inlet Temp Sens Failed Low: circuit voltage low / shorted low | |
| 741 | 1176 | 3 | Turbocharger 1 Compressor Intake Pressure Circuit: circuit voltage high / shorted high | |
| 742 | 1176 | 4 | Turbocharger 1 Compressor Intake Pressure Circuit: circuit voltage low / shorted low | |
| 743 | 1176 | 2 | Turbocharger 1 Compressor Intake Pressure: erratic or intermittent signal | |
| 768 | 923 | 11 | Output Device Driver (VGT or Transmission shift PWM signal): root cause not known | |
| 777 | 1180 | 0 | Turbocharger #1 Turbine Inlet Temperature High: reading above normal (most severe) | |
| 1894 | 641 | 9 | VGT Actuator Driver Circuit: abnormal update rate | |
| 1898 | 641 | 13 | VGT Actuator Controller: out of calibration | |
| 1962 | 641 | 15 | VGT Actuator Driver Over Temperature (Calculated): reading above normal (least severe) | |
| 1976 | 641 | 15 | VGT Actuator Driver Over Temperature (Calculated): reading above normal (least severe) | |
| 2198 | 641 | 11 | VGT Actuator Driver Circuit: root cause not known | |
| 2288 | 103 | 15 | Turbocharger 1 Speed: reading above normal (least severe) | |
| 2346 | 2789 | 15 | Turbocharger Turbine Intake Temperature: reading above normal (least severe) | |
| 2347 | 2629 | 15 | Turbocharger Compressor Outlet Temperature (Calculated): reading above normal (least severe) | |
| 2387 | 641 | 7 | VGT Actuator Driver Circuit (Motor): not responding / out of adjustment | |
| 2449 | 641 | 13 | VGT Actuator Controller: out of calibration | |
| 2451 | 2789 | 16 | Turbocharger Turbine Intake Temperature: reading above normal (moderately severe) | |
| 2634 | 641 | 12 | VGT Actuator Controller: bad device or component | |
| 2635 | 641 | 31 | VGT Actuator Driver Circuit: condition exists | |
| 2636 | 641 | 9 | VGT Actuator Driver Circuit: abnormal update rate | |
| 2973 | 102 | 2 | Intake Manifold 1 Pressure: erratic or intermittent signal | |
| 3348 | 1176 | 1 | Turbocharger 1 Compressor Intake Pressure: reading below normal (most severe) | |
| 3361 | 102 | 10 | Intake Manifold 1 Pressure: abnormal rate of change | |
| 3369 | 1172 | 9 | Turbocharger 1 Compressor Intake Temperature Sensor: abnormal update rate | |
| 3372 | 1176 | 9 | Turbocharger 1 Compressor Intake Pressure: abnormal update rate | |
| 3616 | 2633 | 7 | Engine VGT Nozzle Position: not responding / out of adjustment | |
| 3683 | 1127 | 7 | Engine Turbocharger 1 Boost Pressure: not responding / out of adjustment | |
| 3917 | 104 | 18 | Engine Turbocharger Lube Oil Pressure: reading below normal (moderately severe) | |
| 4956 | 6713 | 13 | VGT Actuator Software: out of calibration | |
| 4957 | 6713 | 31 | VGT Actuator Software: condition exists | |
| 5177 | 6713 | 9 | VGT Actuator Driver Circuit: abnormal update rate |
High-pressure fuel system (common rail) 106 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 112 | 635 | 7 | Engine Timing Actuator is not responding to ECM commands: not responding / out of adjustment | |
| 113 | 635 | 3 | Engine Timing Actuator Circuit: circuit voltage high / shorted high | |
| 114 | 635 | 4 | Engine Timing Actuator Circuit: circuit voltage low / shorted low | |
| 116 | 156 | 3 | Fuel Timing Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 117 | 156 | 4 | Fuel Timing Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 118 | 135 | 3 | Fuel Pump Delivery Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 119 | 135 | 4 | Fuel Pump Delivery Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 166 | 733 | 3 | Rack Position Sensor #1 Circuit: circuit voltage high / shorted high | |
| 172 | 638 | 6 | Rack Actuator Position #1 Circuit: circuit grounded / current high | |
| 173 | 638 | 7 | Rack Actuator: not responding / out of adjustment | |
| 254 | 632 | 4 | Fuel Shutoff Valve Circuit: circuit voltage low / shorted low | |
| 255 | 632 | 3 | Fuel Shutoff Valve Circuit: circuit voltage high / shorted high | |
| 259 | 632 | 7 | Fuel Shutoff Valve: not responding / out of adjustment | |
| 268 | 94 | 2 | Fuel Pressure Sensor Circuit: erratic or intermittent signal | |
| 271 | 1347 | 4 | Engine Fuel Pump Pressurizing Assembly 1 Circuit: circuit voltage low / shorted low | |
| 272 | 1347 | 3 | Engine Fuel Pump Pressurizing Assembly 1 Circuit: circuit voltage high / shorted high | |
| 273 | 1348 | 4 | High Fuel Pressure Solenoid Valve #2 Circuit: circuit voltage low / shorted low | |
| 274 | 1348 | 3 | High Fuel Pressure Solenoid Valve #2 Circuit: circuit voltage high / shorted high | |
| 275 | 1347 | 7 | Fuel Pumping Element #1 (Front): not responding / out of adjustment | |
| 276 | 633 | 3 | Fuel Injection Control Valve Circuit: circuit voltage high / shorted high | |
| 277 | 633 | 7 | Fuel Injection Control Valve: not responding / out of adjustment | |
| 278 | 1075 | 11 | Fuel Priming Pump Control Circuit: root cause not known | |
| 279 | 633 | 4 | Fuel Injection Control Valve Circuit: circuit voltage low / shorted low | |
| 281 | 1347 | 7 | Engine Fuel Pump Pressurizing Assembly 1: not responding / out of adjustment | |
| 282 | 1348 | 7 | High Fuel Pressure Solenoid Valve #2: not responding / out of adjustment | |
| 316 | 931 | 3 | Fuel Supply Pump Actuator Circuit: circuit voltage high / shorted high | |
| 318 | 931 | 7 | Fuel Supply Pump Actuator: not responding / out of adjustment | |
| 328 | 1348 | 7 | Fuel Pumping Element #2 (Rear): not responding / out of adjustment | |
| 329 | 1077 | 14 | Fuel System Leakage error: special instructions | |
| 361 | 1076 | 3 | Fuel Pump Control Module, Fuel Control Valve Circuit: circuit voltage high / shorted high | |
| 362 | 1076 | 4 | Fuel Pump Control Module, Fuel Control Valve Circuit: circuit voltage low / shorted low | |
| 363 | 1076 | 7 | Fuel Pump Control Module, Fuel Control Valve: not responding / out of adjustment | |
| 364 | 1077 | 9 | Fuel Pump Control Module, CAN Communication Error: abnormal update rate | |
| 365 | 1077 | 4 | Fuel Pump Control Module, Supply Voltage Circuit: circuit voltage low / shorted low | |
| 366 | 1077 | 2 | Fuel Pump Control Module, Supply Voltage Circuit: erratic or intermittent signal | |
| 367 | 1078 | 11 | Fuel Pump Control Module, Increment Angle Time Sensor Error: root cause not known | |
| 368 | 1078 | 8 | Fuel Pump Control Module, Timing Error: abnormal frequency or signal | |
| 369 | 1078 | 2 | Fuel Pump Control Module, Engine Synchronization Error: erratic or intermittent signal | |
| 372 | 1077 | 11 | Fuel Pump Control Module, Idle Validation Error: root cause not known | |
| 373 | 1077 | 3 | Fuel Pump Control Module, Fuel Shutoff Error: circuit voltage high / shorted high | |
| 374 | 1077 | 12 | Fuel Pump Control Module, Self-Test Error: bad device or component | |
| 375 | 629 | 2 | Fuel Pump Control Module, Electronic Calibration Code Error: erratic or intermittent signal | |
| 376 | 1077 | 13 | Fuel Pump Control Module, Fueling or Engine Speed Mismatch: out of calibration | |
| 377 | 1077 | 7 | Fuel Pump Control Module, Stuck Relay Error: not responding / out of adjustment | |
| 378 | 633 | 5 | Fueling Actuator #1 Circuit: circuit open / current low | |
| 379 | 633 | 6 | Fueling Actuator #1 Circuit: circuit grounded / current high | |
| 391 | 632 | 11 | Fuel Shutoff Valve Supply Voltage error: root cause not known | |
| 394 | 635 | 5 | Timing Actuator #1 Circuit: circuit open / current low | |
| 395 | 635 | 6 | Timing Actuator #1 Circuit: circuit grounded / current high | |
| 396 | 1244 | 5 | Fueling Actuator #2 Circuit: circuit open / current low | |
| 397 | 1244 | 6 | Fueling Actuator #2 Circuit: circuit grounded / current high | |
| 398 | 1245 | 5 | Timing Actuator #2 Circuit: circuit open / current low | |
| 399 | 1245 | 6 | Timing Actuator #2 Circuit: circuit grounded / current high | |
| 423 | 156 | 2 | Fuel Timing Pressure or Timing Actuator Stuck: erratic or intermittent signal | |
| 449 | 157 | 0 | Injector Metering Rail 1 Pressure: reading above normal (most severe) | |
| 451 | 157 | 3 | Injector Metering Rail 1 Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 452 | 157 | 4 | Injector Metering Rail 1 Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 455 | 633 | 3 | Fuel Control Valve Circuit: circuit voltage high / shorted high | |
| 467 | 635 | 2 | Timing Rail Actuator Circuit: erratic or intermittent signal | |
| 468 | 633 | 2 | Fuel Rail Actuator Circuit: erratic or intermittent signal | |
| 482 | 94 | 18 | Fuel Pressure Low: reading below normal (moderately severe) | |
| 483 | 1349 | 3 | Injector Metering Rail 2 Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 484 | 1349 | 4 | Injector Metering Rail 2 Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 485 | 1349 | 16 | Injector Metering Rail #2 Pressure High: reading above normal (moderately severe) | |
| 486 | 1349 | 18 | Injector Metering Rail #2 Pressure Low: reading below normal (moderately severe) | |
| 514 | 633 | 7 | Fuel Control Valve: not responding / out of adjustment | |
| 517 | 1076 | 12 | Fuel Metering Solenoid: bad device or component | |
| 553 | 157 | 16 | Injector Metering Rail 1 Pressure: reading above normal (moderately severe) | |
| 554 | 157 | 2 | Injector Metering Rail 1 Pressure: erratic or intermittent signal | |
| 559 | 157 | 18 | Injector Metering Rail 1 Pressure: reading below normal (moderately severe) | |
| 581 | 1381 | 3 | Fuel Supply Pump Inlet Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 582 | 1381 | 4 | Fuel Supply Pump Inlet Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 583 | 1381 | 18 | Fuel Supply Pump Inlet Pressure Low: reading below normal (moderately severe) | |
| 755 | 157 | 7 | Injector Metering Rail 1 Pressure: not responding / out of adjustment | |
| 758 | 1349 | 7 | Injector Metering Rail #2 Pressure Malfunction: not responding / out of adjustment | |
| 1923 | 3482 | 3 | Fuel Shutoff Valve Circuit: circuit voltage high / shorted high | |
| 1924 | 3482 | 4 | Fuel Shutoff Valve Circuit: circuit voltage low / shorted low | |
| 1925 | 3482 | 2 | Fuel Shutoff Valve: erratic or intermittent signal | |
| 1926 | 3480 | 2 | Fuel Pressure Sensor: erratic or intermittent signal | |
| 1927 | 3480 | 3 | Fuel Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 1928 | 3480 | 4 | Fuel Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 1963 | 3482 | 7 | Fuel Shutoff Valve: not responding / out of adjustment | |
| 2215 | 94 | 18 | Fuel Pump Delivery Pressure: reading below normal (moderately severe) | |
| 2249 | 157 | 1 | Injector Metering Rail 1 Pressure: reading below normal (most severe) | |
| 2261 | 94 | 15 | Fuel Pump Delivery Pressure: reading above normal (least severe) | |
| 2262 | 94 | 17 | Fuel Pump Delivery Pressure: reading below normal (least severe) | |
| 2311 | 633 | 31 | Electronic Fuel Injection Control Valve Circuit: condition exists | |
| 2741 | 3482 | 13 | Fuel Shutoff Valve Swapped: out of calibration | |
| 2881 | 3480 | 17 | Fuel Pressure Sensor: reading below normal (least severe) | |
| 3337 | 5395 | 16 | Engine Idle Fuel Quantity: reading above normal (moderately severe) | |
| 3338 | 5395 | 18 | Engine Idle Fuel Quantity: reading below normal (moderately severe) | |
| 3727 | 5571 | 7 | High Pressure Common Rail Fuel Pressure Relief Valve: not responding / out of adjustment | |
| 3741 | 5571 | 0 | High Pressure Common Rail Fuel Pressure Relief Valve: reading above normal (most severe) | |
| 4262 | 5571 | 3 | High Pressure Common Rail Fuel Pressure Relief Valve: circuit voltage high / shorted high | |
| 4263 | 5571 | 4 | High Pressure Common Rail Fuel Pressure Relief Valve: circuit voltage low / shorted low | |
| 4265 | 5571 | 11 | High Pressure Common Rail Fuel Pressure Relief Valve: root cause not known | |
| 4284 | 5793 | 9 | Desired Engine Fueling State: abnormal update rate | |
| 4568 | 3482 | 16 | Fuel Shutoff Valve: reading above normal (moderately severe) | |
| 4691 | 5585 | 18 | Engine Injector Metering Rail 1 Cranking Pressure: reading below normal (moderately severe) | |
| 4726 | 1239 | 16 | Engine Fuel Leakage: reading above normal (moderately severe) | |
| 4727 | 157 | 15 | Injector Metering Rail 1 Pressure: reading above normal (least severe) | |
| 4841 | 6653 | 16 | Cold Start Injector Metering Rail 1 Pressure: reading above normal (moderately severe) | |
| 4867 | 5571 | 31 | High Pressure Common Rail Fuel Pressure Relief Valve: condition exists | |
| 4936 | 5380 | 11 | Engine Fuel Valve 1: root cause not known | |
| 4937 | 5380 | 13 | Engine Fuel Valve 1: out of calibration | |
| 5585 | 5571 | 15 | High Pressure Common Rail Fuel Pressure Relief Valve: reading above normal (least severe) |
Fuel supply and water in fuel 20 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 261 | 174 | 16 | Engine Fuel Temperature: reading above normal (moderately severe) | |
| 263 | 174 | 3 | Engine Fuel Temperature Sensor 1 Circuit: circuit voltage high / shorted high | |
| 264 | 174 | 11 | Fuel Temperature Sensor Circuit: root cause not known | |
| 265 | 174 | 4 | Engine Fuel Temperature Sensor 1 Circuit: circuit voltage low / shorted low | |
| 266 | 174 | 0 | Engine Fuel Temperature: reading above normal (most severe) | |
| 418 | 97 | 15 | Water in Fuel Indicator: reading above normal (least severe) | |
| 428 | 97 | 3 | Water in Fuel Indicator Sensor Circuit: circuit voltage high / shorted high | |
| 429 | 97 | 4 | Water in Fuel Indicator Sensor Circuit: circuit voltage low / shorted low | |
| 535 | 174 | 2 | Engine Fuel Temperature: erratic or intermittent signal | |
| 546 | 94 | 3 | Fuel Delivery Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 547 | 94 | 4 | Fuel Delivery Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 1852 | 97 | 16 | Water in Fuel Indicator: reading above normal (moderately severe) | |
| 2265 | 1075 | 3 | Electric Lift Pump for Engine Fuel Supply Circuit: circuit voltage high / shorted high | |
| 2266 | 1075 | 4 | Electric Lift Pump for Engine Fuel Supply Circuit: circuit voltage low / shorted low | |
| 2372 | 95 | 16 | Fuel Filter Differential Pressure: reading above normal (moderately severe) | |
| 4615 | 94 | 0 | Engine Fuel Delivery Pressure: reading above normal (most severe) | |
| 4688 | 6301 | 3 | Water in Fuel Indicator 2 Sensor Circuit: circuit voltage high / shorted high | |
| 4689 | 6301 | 4 | Water in Fuel Indicator 2 Sensor Circuit: circuit voltage low / shorted low | |
| 6258 | 1075 | 3 | Electric Lift Pump for Engine Fuel Supply Circuit: circuit voltage high / shorted high | |
| 6259 | 1075 | 4 | Electric Lift Pump for Engine Fuel Supply Circuit: circuit voltage low / shorted low |
Injectors and misfire 38 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 311 | 651 | 6 | Injector Solenoid Valve Cylinder #1 Circuit: circuit grounded / current high | |
| 312 | 655 | 6 | Injector Solenoid Valve Cylinder #5 Circuit: circuit grounded / current high | |
| 313 | 653 | 6 | Injector Solenoid Valve Cylinder #3 Circuit: circuit grounded / current high | |
| 314 | 656 | 6 | Injector Solenoid Valve Cylinder #6 Circuit: circuit grounded / current high | |
| 315 | 652 | 6 | Injector Solenoid Valve Cylinder #2 Circuit: circuit grounded / current high | |
| 321 | 654 | 6 | Injector Solenoid Valve Cylinder #4 Circuit: circuit grounded / current high | |
| 322 | 651 | 5 | Injector Solenoid Driver Cylinder 1 Circuit: circuit open / current low | |
| 323 | 655 | 5 | Injector Solenoid Driver Cylinder 5 Circuit: circuit open / current low | |
| 324 | 653 | 5 | Injector Solenoid Driver Cylinder 3 Circuit: circuit open / current low | |
| 325 | 656 | 5 | Injector Solenoid Driver Cylinder 6 Circuit: circuit open / current low | |
| 331 | 652 | 5 | Injector Solenoid Driver Cylinder 2 Circuit: circuit open / current low | |
| 332 | 654 | 5 | Injector Solenoid Driver Cylinder 4 Circuit: circuit open / current low | |
| 539 | 633 | 11 | Injector Control Valve Electronic Filter (Transorb) Error: root cause not known | |
| 1139 | 651 | 7 | Injector Solenoid Driver Cylinder 1: not responding / out of adjustment | |
| 1141 | 652 | 7 | Injector Solenoid Driver Cylinder 2: not responding / out of adjustment | |
| 1142 | 653 | 7 | Injector Solenoid Driver Cylinder 3: not responding / out of adjustment | |
| 1143 | 654 | 7 | Injector Solenoid Driver Cylinder 4: not responding / out of adjustment | |
| 1144 | 655 | 7 | Injector Solenoid Driver Cylinder 5: not responding / out of adjustment | |
| 1145 | 656 | 7 | Injector Solenoid Driver Cylinder 6: not responding / out of adjustment | |
| 1548 | 657 | 5 | Injector Solenoid Driver Cylinder 7 Circuit: circuit open / current low | |
| 1549 | 658 | 5 | Injector Solenoid Driver Cylinder 8 Circuit: circuit open / current low | |
| 1551 | 660 | 5 | Injector Solenoid Driver Cylinder 10 Circuit: circuit open / current low | |
| 1552 | 661 | 5 | Injector Solenoid Driver Cylinder 11 Circuit: circuit open / current low | |
| 1553 | 662 | 5 | Injector Solenoid Driver Cylinder 12 Circuit: circuit open / current low | |
| 1554 | 663 | 5 | Injector Solenoid Driver Cylinder 13 Circuit: circuit open / current low | |
| 1555 | 664 | 5 | Injector Solenoid Driver Cylinder 14 Circuit: circuit open / current low | |
| 1556 | 665 | 5 | Injector Solenoid Driver Cylinder 15 Circuit: circuit open / current low | |
| 1557 | 666 | 5 | Injector Solenoid Driver Cylinder 16 Circuit: circuit open / current low | |
| 1622 | 659 | 5 | Injector Solenoid Driver Cylinder 9 Circuit: circuit open / current low | |
| 1654 | 1323 | 31 | Engine Misfire Cylinder 1: condition exists | |
| 1655 | 1324 | 31 | Engine Misfire Cylinder 2: condition exists | |
| 1656 | 1325 | 31 | Engine Misfire Cylinder 3: condition exists | |
| 1657 | 1326 | 31 | Engine Misfire Cylinder 4: condition exists | |
| 1658 | 1327 | 31 | Engine Misfire Cylinder 5: condition exists | |
| 1659 | 1328 | 31 | Engine Misfire Cylinder 6: condition exists | |
| 1718 | 1322 | 31 | Engine Misfire for Multiple Cylinders: condition exists | |
| 2765 | 2797 | 13 | Engine Injector Bank 1 Barcodes: out of calibration | |
| 4713 | 5357 | 31 | Engine Fuel Injection Quantity Error for Multiple Cylinders: condition exists |
Engine cooling 26 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 144 | 110 | 3 | Engine Coolant Temperature 1 Sensor Circuit: circuit voltage high / shorted high | |
| 145 | 110 | 4 | Engine Coolant Temperature 1 Sensor Circuit: circuit voltage low / shorted low | |
| 146 | 110 | 16 | Engine Coolant Temperature: reading above normal (moderately severe) | |
| 151 | 110 | 0 | Engine Coolant Temperature: reading above normal (most severe) | |
| 195 | 111 | 3 | Coolant Level Sensor 1 Circuit: circuit voltage high / shorted high | |
| 196 | 111 | 4 | Coolant Level Sensor 1 Circuit: circuit voltage low / shorted low | |
| 197 | 111 | 18 | Coolant Level: reading below normal (moderately severe) | |
| 231 | 109 | 3 | Coolant Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 232 | 109 | 4 | Coolant Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 233 | 109 | 18 | Coolant Pressure: reading below normal (moderately severe) | |
| 235 | 111 | 1 | Coolant Level: reading below normal (most severe) | |
| 334 | 110 | 2 | Engine Coolant Temperature: erratic or intermittent signal | |
| 422 | 111 | 2 | Coolant Level: erratic or intermittent signal | |
| 611 | 1383 | 31 | Engine Shut Down Hot: condition exists | |
| 1847 | 110 | 14 | Engine Coolant Temperature: special instructions | |
| 2448 | 111 | 17 | Coolant Level: reading below normal (least severe) | |
| 2646 | 110 | 31 | Engine Coolant Temperature: condition exists | |
| 2659 | 110 | 31 | Engine Coolant Temperature: condition exists | |
| 2789 | 110 | 18 | Engine Coolant Temperature: reading below normal (moderately severe) | |
| 2963 | 110 | 15 | Engine Coolant Temperature: reading above normal (least severe) | |
| 3243 | 3060 | 18 | Engine Cooling System Monitor: reading below normal (moderately severe) | |
| 3366 | 111 | 18 | Coolant Level: reading below normal (moderately severe) | |
| 3613 | 111 | 9 | Coolant Level Sensor: abnormal update rate | |
| 5167 | 111 | 17 | Coolant Level: reading below normal (least severe) | |
| 6522 | 111 | 3 | Coolant Level Sensor 1 Circuit: circuit voltage high / shorted high | |
| 6523 | 111 | 4 | Coolant Level Sensor 1 Circuit: circuit voltage low / shorted low |
Cooling fan 20 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 245 | 647 | 4 | Fan Control Circuit: circuit voltage low / shorted low | |
| 389 | 647 | 11 | Fan Clutch Circuit Error: root cause not known | |
| 2377 | 647 | 3 | Fan Control Circuit: circuit voltage high / shorted high | |
| 3633 | 5484 | 3 | Engine Fan Clutch 2 Control Circuit: circuit voltage high / shorted high | |
| 3634 | 5484 | 4 | Engine Fan Clutch 2 Control Circuit: circuit voltage low / shorted low | |
| 4789 | 1639 | 0 | Fan Speed: reading above normal (most severe) | |
| 4791 | 1639 | 1 | Fan Speed: reading below normal (most severe) | |
| 5183 | 6799 | 3 | Fan Blade Pitch Position Sensor Circuit: circuit voltage high / shorted high | |
| 5184 | 6799 | 4 | Fan Blade Pitch Position Sensor Circuit: circuit voltage low / shorted low | |
| 5185 | 6799 | 7 | Fan Blade Pitch: not responding / out of adjustment | |
| 6263 | 647 | 3 | Fan Control Circuit: circuit voltage high / shorted high | |
| 6264 | 647 | 4 | Fan Control Circuit: circuit voltage low / shorted low | |
| 6456 | 5484 | 3 | Engine Fan Clutch 2 Control Circuit: circuit voltage high / shorted high | |
| 6457 | 5484 | 4 | Engine Fan Clutch 2 Control Circuit: circuit voltage low / shorted low | |
| 6467 | 1639 | 15 | Fan Speed: reading above normal (least severe) | |
| 6468 | 1639 | 17 | Fan Speed: reading below normal (least severe) | |
| 6469 | 1639 | 2 | Fan Speed: erratic or intermittent signal | |
| 6471 | 6799 | 3 | Fan Blade Pitch Position Sensor Circuit: circuit voltage high / shorted high | |
| 6472 | 6799 | 4 | Fan Blade Pitch Position Sensor Circuit: circuit voltage low / shorted low | |
| 6473 | 6799 | 2 | Fan Blade Pitch: erratic or intermittent signal |
Engine oil 28 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 135 | 100 | 3 | Engine Oil Rifle Pressure 1 Sensor Circuit: circuit voltage high / shorted high | |
| 136 | 1208 | 3 | Pre Filter Oil Pressure Sensor Circuit Failed High: circuit voltage high / shorted high | |
| 137 | 1208 | 4 | Pre Filter Oil Pressure Sensor Circuit Failed Low: circuit voltage low / shorted low | |
| 141 | 100 | 4 | Engine Oil Rifle Pressure 1 Sensor Circuit: circuit voltage low / shorted low | |
| 143 | 100 | 18 | Engine Oil Rifle Pressure: reading below normal (moderately severe) | |
| 212 | 175 | 3 | Engine Oil Temperature Sensor 1 Circuit: circuit voltage high / shorted high | |
| 213 | 175 | 4 | Engine Oil Temperature Sensor 1 Circuit: circuit voltage low / shorted low | |
| 214 | 175 | 0 | Engine Oil Temperature: reading above normal (most severe) | |
| 219 | 1380 | 1 | Low Oil Level in the Centinel makeup oil tank: reading below normal (most severe) | |
| 223 | 1265 | 4 | Engine Oil Burn Valve Solenoid Circuit: circuit voltage low / shorted low | |
| 225 | 1266 | 4 | Engine Oil Replacement Valve Solenoid Circuit: circuit voltage low / shorted low | |
| 252 | 98 | 2 | Engine Oil Level #1 Sensor Circuit: erratic or intermittent signal | |
| 253 | 98 | 1 | Engine Oil Level: reading below normal (most severe) | |
| 415 | 100 | 1 | Engine Oil Rifle Pressure: reading below normal (most severe) | |
| 421 | 175 | 16 | Engine Oil Temperature: reading above normal (moderately severe) | |
| 425 | 175 | 2 | Engine Oil Temperature: erratic or intermittent signal | |
| 435 | 100 | 2 | Engine Oil Rifle Pressure: erratic or intermittent signal | |
| 471 | 98 | 17 | Engine Oil Level: reading below normal (least severe) | |
| 473 | 1380 | 2 | Engine Oil Level #2 Low: erratic or intermittent signal | |
| 612 | 99 | 1 | High Lubricating Oil Filter Restriction: reading below normal (most severe) | |
| 649 | 1378 | 31 | Engine Oil Change Interval: condition exists | |
| 688 | 98 | 0 | Engine Oil Level: reading above normal (most severe) | |
| 1428 | 4186 | 31 | Low Oil Pressure (LOP) Shutdown Relay Driver Diagnostic has detected an error: condition exists | |
| 1431 | 4188 | 31 | Pre-Low Oil Pressure Warning Relay Driver Diagnostic has detected an error: condition exists | |
| 2154 | 611 | 3 | Post-Filter Oil Pressure Sensor Circuit- Shorted high: circuit voltage high / shorted high | |
| 2155 | 611 | 4 | Post-Filter Oil Pressure Sensor Circuit- Shorted Low: circuit voltage low / shorted low | |
| 6524 | 175 | 3 | Engine Oil Temperature Sensor 1 Circuit: circuit voltage high / shorted high | |
| 6525 | 175 | 4 | Engine Oil Temperature Sensor 1 Circuit: circuit voltage low / shorted low |
Crankcase and ventilation 17 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 555 | 101 | 16 | Crankcase Pressure: reading above normal (moderately severe) | |
| 556 | 101 | 0 | Crankcase Pressure: reading above normal (most severe) | |
| 719 | 1264 | 3 | Crankcase Blowby Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 729 | 1264 | 4 | Crankcase Blowby Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 1843 | 101 | 3 | Crankcase Pressure Circuit: circuit voltage high / shorted high | |
| 1844 | 101 | 4 | Crankcase Pressure Circuit: circuit voltage low / shorted low | |
| 1942 | 101 | 2 | Crankcase Pressure: erratic or intermittent signal | |
| 1974 | 101 | 15 | Crankcase Pressure: reading above normal (least severe) | |
| 2699 | 520320 | 7 | Crankcase Depression Valve: not responding / out of adjustment | |
| 3377 | 5396 | 31 | Engine Crankcase Ventilation Hose Disconnected: condition exists | |
| 3733 | 862 | 3 | Crankcase Breather Filter Heater Circuit: circuit voltage high / shorted high | |
| 3734 | 862 | 4 | Crankcase Breather Filter Heater Circuit: circuit voltage low / shorted low | |
| 4286 | 520595 | 3 | Closed Crankcase Ventilation System Pressure Sensor: circuit voltage high / shorted high | |
| 4287 | 520595 | 4 | Closed Crankcase Ventilation System Pressure Sensor: circuit voltage low / shorted low | |
| 4288 | 520595 | 2 | Closed Crankcase Ventilation System Pressure: erratic or intermittent signal | |
| 6336 | 862 | 3 | Crankcase Breather Filter Heater Circuit: circuit voltage high / shorted high | |
| 6337 | 862 | 4 | Crankcase Breather Filter Heater Circuit: circuit voltage low / shorted low |
Intake air and environment sensors 35 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 126 | 1129 | 16 | High Intake Manifold Pressure Right Bank: reading above normal (moderately severe) | |
| 127 | 1129 | 18 | Low Intake Manifold Pressure Right Bank: reading below normal (moderately severe) | |
| 128 | 1129 | 3 | Right Bank Intake Manifold Pressure Sensor Circuit Failed High: circuit voltage high / shorted high | |
| 129 | 1129 | 4 | Right Bank Intake Manifold Pressure Sensor Circuit Failed Low: circuit voltage low / shorted low | |
| 153 | 105 | 3 | Intake Manifold 1 Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 154 | 105 | 4 | Intake Manifold 1 Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 155 | 105 | 0 | Intake Manifold 1 Temperature: reading above normal (most severe) | |
| 156 | 1131 | 3 | Left Bank Rear Intake Manifold Temp Sensor Circuit Failed High: circuit voltage high / shorted high | |
| 157 | 1131 | 4 | Left Bank Rear Intake Manifold Temp Sensor Circuit Failed Low: circuit voltage low / shorted low | |
| 158 | 1131 | 0 | High Intake Manifold Temp: reading above normal (most severe) | |
| 159 | 1132 | 3 | Right Bank Front Intake Manifold Temperature Sensor Circuit Failed High: circuit voltage high / shorted high | |
| 161 | 1132 | 4 | Right Bank Front Intake Manifold Temperature Sensor Circuit Failed Low: circuit voltage low / shorted low | |
| 162 | 1132 | 0 | High Intake Manifold Temperature: reading above normal (most severe) | |
| 163 | 1133 | 3 | Right Bank Rear Intake Manifold Temperature Sensor Circuit Failed High: circuit voltage high / shorted high | |
| 164 | 1133 | 4 | Right Bank Rear Intake Manifold Temperature Sensor Circuit Failed Low: circuit voltage low / shorted low | |
| 165 | 1133 | 0 | High Intake Manifold Temperature: reading above normal (most severe) | |
| 221 | 108 | 3 | Barometric Pressure Sensor Circuit: circuit voltage high / shorted high | |
| 222 | 108 | 4 | Barometric Pressure Sensor Circuit: circuit voltage low / shorted low | |
| 249 | 171 | 3 | Ambient Air Temperature Sensor 1 Circuit: circuit voltage high / shorted high | |
| 256 | 171 | 4 | Ambient Air Temperature Sensor 1 Circuit: circuit voltage low / shorted low | |
| 295 | 108 | 2 | Barometric Pressure: erratic or intermittent signal | |
| 419 | 1319 | 2 | Intake Manifold Boost Pressure Imbalance: erratic or intermittent signal | |
| 436 | 105 | 2 | Intake Manifold 1 Temperature: erratic or intermittent signal | |
| 488 | 105 | 16 | Intake Manifold 1 Temperature: reading above normal (moderately severe) | |
| 1943 | 3555 | 17 | Ambient Air Density: reading below normal (least severe) | |
| 2398 | 171 | 2 | Ambient Air Temperature: erratic or intermittent signal | |
| 2571 | 2630 | 3 | Engine Charge Air Cooler Outlet Temperature: circuit voltage high / shorted high | |
| 2572 | 2630 | 4 | Engine Charge Air Cooler Outlet Temperature: circuit voltage low / shorted low | |
| 2964 | 105 | 15 | Intake Manifold 1 Temperature: reading above normal (least severe) | |
| 3341 | 107 | 16 | Engine Air Filter Differential Pressure: reading above normal (moderately severe) | |
| 3367 | 4490 | 9 | Specific Humidity Sensor: abnormal update rate | |
| 3385 | 105 | 18 | Intake Manifold 1 Temperature: reading below normal (moderately severe) | |
| 3478 | 2630 | 2 | Engine Charge Air Cooler Outlet Temperature: erratic or intermittent signal | |
| 3531 | 171 | 9 | Ambient Air Temperature: abnormal update rate | |
| 5576 | 107 | 15 | Engine Air Filter Differential Pressure: reading above normal (least severe) |
Engine speed and position sensors 16 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 115 | 612 | 2 | Engine Magnetic Speed/Position Lost Both of Two Signals: erratic or intermittent signal | |
| 121 | 190 | 10 | Engine Speed/Position Sensor Circuit: abnormal rate of change | |
| 234 | 190 | 0 | Engine Crankshaft Speed/Position: reading above normal (most severe) | |
| 283 | 1043 | 3 | Engine Speed/Position Sensor #1 (Crankshaft) Supply Voltage Circuit: circuit voltage high / shorted high | |
| 284 | 1043 | 4 | Engine Speed/Position Sensor #1 (Crankshaft) Supply Voltage Circuit: circuit voltage low / shorted low | |
| 496 | 1043 | 11 | Engine Speed/Position Sensor #2 (Camshaft) Supply Voltage: root cause not known | |
| 497 | 1377 | 2 | Multiple Unit Synchronization Switch: erratic or intermittent signal | |
| 523 | 611 | 2 | Auxiliary Intermediate (PTO) Speed Switch Validation: erratic or intermittent signal | |
| 689 | 190 | 2 | Engine Crankshaft Speed/Position: erratic or intermittent signal | |
| 731 | 723 | 7 | Engine Speed / Position Camshaft and Crankshaft Misalignment: not responding / out of adjustment | |
| 753 | 723 | 2 | Engine Speed/Position #2: erratic or intermittent signal | |
| 778 | 723 | 2 | Engine Camshaft Speed / Position Sensor: erratic or intermittent signal | |
| 1992 | 190 | 16 | Engine Crankshaft Speed/Position: reading above normal (moderately severe) | |
| 2321 | 190 | 2 | Engine Crankshaft Speed/Position: erratic or intermittent signal | |
| 2322 | 723 | 2 | Engine Camshaft Speed / Position Sensor: erratic or intermittent signal | |
| 2468 | 190 | 16 | Engine Crankshaft Speed/Position: reading above normal (moderately severe) |
Exhaust temperature sensors 33 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 479 | 1318 | 9 | Exhaust Port Temperature Bank Imbalance: abnormal update rate | |
| 641 | 1137 | 0 | High #1 LB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 642 | 1138 | 0 | High #2 LB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 643 | 1139 | 0 | High #3 LB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 644 | 1140 | 0 | High #4 LB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 645 | 1141 | 0 | High #5 LB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 646 | 1142 | 0 | High #6 LB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 647 | 1143 | 0 | High #7 LB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 648 | 1144 | 0 | High #8 LB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 651 | 1143 | (30,45) | High #1 RB Cylinder Exhaust Temperature: fault | |
| 652 | 1144 | (30,45) | High #2 RB Cylinder Exhaust Temperature: fault | |
| 653 | 1145 | (30,45) | High #3 RB Cylinder Exhaust Temperature: fault | |
| 654 | 1146 | (30,45) | High #4 RB Cylinder Exhaust Temperature: fault | |
| 655 | 1147 | (30,45) | High #5 RB Cylinder Exhaust Temperature: fault | |
| 656 | 1148 | (30,45) | High #6 RB Cylinder Exhaust Temperature: fault | |
| 657 | 1150 | 0 | High #7 RB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 658 | 1151 | 0 | High #8 RB Cylinder Exhaust Temperature: reading above normal (most severe) | |
| 671 | 1137 | 4 | Cyl #1 LB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low | |
| 672 | 1138 | 4 | Cyl #2 LB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low | |
| 673 | 1139 | 4 | Cyl #3 LB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low | |
| 674 | 1140 | 4 | Cyl #4 LB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low | |
| 675 | 1141 | 4 | Cyl #5 LB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low | |
| 676 | 1142 | 4 | Cyl #6 LB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low | |
| 677 | 1143 | 4 | Cyl #7 LB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low | |
| 678 | 1144 | 4 | Cyl #8 LB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low | |
| 721 | 1143 | (30,45) | Cyl #1 RB Exhaust Temp Sens Failed Low: fault | |
| 722 | 1144 | (30,45) | Cyl #2 RB Exhaust Temp Sens Failed Low: fault | |
| 723 | 1145 | (30,45) | Cyl #3 RB Exhaust Temp Sens Failed Low: fault | |
| 724 | 1146 | (30,45) | Cyl #4 RB Exhaust Temp Sens Failed Low: fault | |
| 725 | 1147 | (30,45) | Cyl #5 RB Exhaust Temp Sens Failed Low: fault | |
| 726 | 1148 | (30,45) | Cyl #6 RB Exhaust Temp Sens Failed Low: fault | |
| 727 | 1151 | 4 | Cyl #7 RB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low | |
| 728 | 1152 | 4 | Cyl #8 RB Exhaust Temp Sens Failed Low: circuit voltage low / shorted low |
Intake air heater and cold start 11 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 381 | 626 | 11 | Intake Air Heater (Relay Enable) #1 Circuit: root cause not known | |
| 382 | 626 | 11 | Intake Air Heater (Relay Enable) #2 Circuit: root cause not known | |
| 384 | 626 | 11 | Start Assist Device Control Circuit Error (Ether Injection): root cause not known | |
| 2555 | 729 | 3 | Engine Intake Air Heater 1 Circuit: circuit voltage high / shorted high | |
| 2556 | 729 | 4 | Engine Intake Air Heater 1 Circuit: circuit voltage low / shorted low | |
| 3222 | 520435 | 12 | Glow Plug Module: bad device or component | |
| 3494 | 1081 | 7 | Engine Wait to Start Lamp: not responding / out of adjustment | |
| 3555 | 1081 | 9 | Engine Wait to Start Lamp: abnormal update rate | |
| 4252 | 1081 | 31 | Engine Wait to Start Lamp: condition exists | |
| 6556 | 729 | 3 | Engine Intake Air Heater 1 Circuit: circuit voltage high / shorted high | |
| 6557 | 729 | 4 | Engine Intake Air Heater 1 Circuit: circuit voltage low / shorted low |
Engine brake and exhaust back pressure 24 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 243 | 513 | 4 | Engine Brake Driver #1 Circuit: circuit voltage low / shorted low | |
| 2182 | 1072 | 3 | Engine Brake Actuator Driver 1 Circuit: circuit voltage high / shorted high | |
| 2183 | 1072 | 4 | Engine Brake Actuator Driver 1 Circuit: circuit voltage low / shorted low | |
| 2363 | 1073 | 4 | Engine Brake Actuator Driver Output 2 Circuit: circuit voltage low / shorted low | |
| 2365 | 1112 | 4 | Engine Brake Actuator Driver Output 3 Circuit: circuit voltage low / shorted low | |
| 2367 | 1073 | 3 | Engine Brake Actuator Driver Output 2 Circuit: circuit voltage high / shorted high | |
| 2368 | 1112 | 3 | Engine Brake Actuator Driver 3 Circuit: circuit voltage high / shorted high | |
| 2373 | 1209 | 3 | Exhaust Gas Pressure Sensor 1 Circuit: circuit voltage high / shorted high | |
| 2374 | 1209 | 4 | Exhaust Gas Pressure Sensor 1 Circuit: circuit voltage low / shorted low | |
| 2554 | 1209 | 2 | Exhaust Gas Pressure 1: erratic or intermittent signal | |
| 2764 | 1209 | 16 | Exhaust Gas Pressure 1: reading above normal (moderately severe) | |
| 4293 | 5097 | 3 | Engine Brake Active Lamp: circuit voltage high / shorted high | |
| 4294 | 5097 | 4 | Engine Brake Active Lamp: circuit voltage low / shorted low | |
| 5271 | 649 | 3 | Engine Exhaust Back Pressure Regulator Control Circuit: circuit voltage high / shorted high | |
| 5272 | 649 | 4 | Engine Exhaust Back Pressure Regulator Control Circuit: circuit voltage low / shorted low | |
| 5273 | 649 | 5 | Engine Exhaust Back Pressure Regulator Control Circuit: circuit open / current low | |
| 5274 | 5625 | 2 | Engine Exhaust Back Pressure Regulator Position: erratic or intermittent signal | |
| 5275 | 5625 | 3 | Engine Exhaust Back Pressure Regulator Position Sensor Circuit: circuit voltage high / shorted high | |
| 5276 | 5625 | 4 | Engine Exhaust Back Pressure Regulator Position Sensor Circuit: circuit voltage low / shorted low | |
| 5277 | 5626 | 13 | Engine Exhaust Back Pressure Regulator: out of calibration | |
| 6418 | 1072 | 3 | Engine Brake Actuator Driver 1 Circuit: circuit voltage high / shorted high | |
| 6419 | 1072 | 4 | Engine Brake Actuator Driver 1 Circuit: circuit voltage low / shorted low | |
| 6421 | 1073 | 3 | Engine Brake Actuator Driver Output 2 Circuit: circuit voltage high / shorted high | |
| 6422 | 1073 | 4 | Engine Brake Actuator Driver Output 2 Circuit: circuit voltage low / shorted low |
Intake throttle and air shutoff 10 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 3139 | 3667 | 3 | Engine Air Shutoff Circuit: circuit voltage high / shorted high | |
| 3141 | 3667 | 4 | Engine Air Shutoff Circuit: circuit voltage low / shorted low | |
| 4484 | 3667 | 7 | Engine Air Shutoff: not responding / out of adjustment | |
| 5221 | 3667 | 2 | Engine Air Shutoff Status: erratic or intermittent signal | |
| 5292 | 520809 | 31 | Excessive Time Since Last Engine Air Shutoff Maintenance Test: condition exists | |
| 6493 | 3464 | 3 | Electronic Throttle Control Actuator Driver Circuit- Voltage above normal, or shorted to high source: circuit voltage high / shorted high | |
| 6494 | 3464 | 4 | Electronic Throttle Control Actuator Driver Circuit- Voltage above normal, or shorted to low source: circuit voltage low / shorted low | |
| 6496 | 3464 | 5 | Electronic Throttle Control Actuator Driver Circuit- Current Below Normal or Open Circuit: circuit open / current low | |
| 6497 | 51 | 3 | Engine Intake Throttle Actuator Position Sensor Circuit- Voltage above normal, or shorted to high source: circuit voltage high / shorted high | |
| 6498 | 51 | 4 | Engine Intake Throttle Actuator Position Sensor Circuit- Voltage above normal, or shorted to low source: circuit voltage low / shorted low |
Engine protection 3 codes
Accelerator pedal and driver controls 51 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 131 | 91 | 3 | Accelerator Pedal or Lever Position Sensor 1 Circuit: circuit voltage high / shorted high | |
| 132 | 91 | 4 | Accelerator Pedal or Lever Position Sensor 1 Circuit: circuit voltage low / shorted low | |
| 133 | 974 | 3 | Remote Accelerator Pedal or Lever Position Sensor 1 Circuit: circuit voltage high / shorted high | |
| 134 | 974 | 4 | Remote Accelerator Pedal or Lever Position Sensor 1 Circuit: circuit voltage low / shorted low | |
| 147 | 91 | 1 | Accelerator Pedal or Lever Position 1 Sensor Circuit Frequency: reading below normal (most severe) | |
| 148 | 91 | 0 | Accelerator Pedal or Lever Position Sensor 1: reading above normal (most severe) | |
| 193 | 520199 | 3 | Cruise Control (Resistive) Signal Circuit: circuit voltage high / shorted high | |
| 194 | 520199 | 4 | Cruise Control (Resistive) Signal Circuit: circuit voltage low / shorted low | |
| 237 | 644 | 2 | External Speed Command Input (Multiple Unit Synchronization): erratic or intermittent signal | |
| 241 | 84 | 2 | Wheel-Based Vehicle Speed: erratic or intermittent signal | |
| 242 | 84 | 10 | Wheel-Based Vehicle Speed Sensor Circuit tampering has been detected: abnormal rate of change | |
| 287 | 91 | 19 | SAE J1939 Multiplexing Accelerator Pedal Sensor System Error: network data error | |
| 349 | 191 | 16 | Transmission Output Shaft Speed: reading above normal (moderately severe) | |
| 387 | 1043 | 3 | Accelerator Pedal Position Sensor Supply Voltage Circuit: circuit voltage high / shorted high | |
| 431 | 558 | 2 | Accelerator Pedal or Lever Idle Validation Switch: erratic or intermittent signal | |
| 432 | 558 | 13 | Accelerator Pedal or Lever Idle Validation Switch Circuit: out of calibration | |
| 443 | 1043 | 4 | Accelerator Pedal Position Sensor Supply Voltage Circuit: circuit voltage low / shorted low | |
| 489 | 191 | 18 | Transmission Output Shaft Speed: reading below normal (moderately severe) | |
| 551 | 558 | 4 | Accelerator Pedal Idle Validation Circuit: circuit voltage low / shorted low | |
| 769 | 597 | 3 | Brake Switch Circuit: circuit voltage high / shorted high | |
| 771 | 597 | 4 | Brake Switch Circuit: circuit voltage low / shorted low | |
| 784 | 1590 | 2 | Adaptive Cruise Control Mode: erratic or intermittent signal | |
| 1239 | 2623 | 3 | Accelerator Pedal or Lever Position Sensor 2 Circuit: circuit voltage high / shorted high | |
| 1241 | 2623 | 4 | Accelerator Pedal or Lever Position Sensor 2 Circuit: circuit voltage low / shorted low | |
| 1242 | 91 | 2 | Accelerator Pedal or Lever Position Sensor 1: erratic or intermittent signal | |
| 1358 | 91 | 3 | Accelerator Pedal or Lever Position Sensor 1 Circuit: circuit voltage high / shorted high | |
| 1359 | 91 | 4 | Accelerator Pedal or Lever Position Sensor 1 Circuit: circuit voltage low / shorted low | |
| 2721 | 599 | 2 | Cruise Control Set Switch: erratic or intermittent signal | |
| 2755 | 520332 | 3 | Cruise Control (Resistive) #2 Signal Circuit: circuit voltage high / shorted high | |
| 2756 | 520332 | 4 | Cruise Control (Resistive) #2 Signal Circuit: circuit voltage low / shorted low | |
| 2998 | 1632 | 14 | Engine Torque Limit Feature: special instructions | |
| 3186 | 1623 | 9 | Tachograph Output Shaft Speed: abnormal update rate | |
| 3326 | 91 | 9 | SAE J1939 Multiplexed Accelerator Pedal or Lever Sensor System: abnormal update rate | |
| 3328 | 191 | 9 | Transmission Output Shaft Speed: abnormal update rate | |
| 3374 | 1818 | 31 | Roll Over Protection Brake Control Active: condition exists | |
| 3488 | 563 | 9 | Anti-Lock Braking (ABS) Controller: abnormal update rate | |
| 3526 | 84 | 9 | Wheel-Based Vehicle Speed: abnormal update rate | |
| 3528 | 558 | 9 | Accelerator Pedal or Lever Idle Validation Switch: abnormal update rate | |
| 3641 | 748 | 9 | Transmission Output Retarder: abnormal update rate | |
| 3735 | 2884 | 9 | Engine Auxiliary Governor Switch: abnormal update rate | |
| 3839 | 596 | 7 | Cruise Control Enable Switch: not responding / out of adjustment | |
| 3841 | 596 | 2 | Cruise Control Enable Switch: erratic or intermittent signal | |
| 3842 | 596 | 13 | Cruise Control Enable Switch: out of calibration | |
| 3843 | 5603 | 9 | Cruise Control Disable Command: abnormal update rate | |
| 3844 | 5605 | 31 | Cruise Control Pause Command: condition exists | |
| 3845 | 5603 | 31 | Cruise Control Disable Command: condition exists | |
| 4215 | 563 | 31 | Anti-Lock Braking (ABS) Active: condition exists | |
| 4526 | 521 | 2 | Brake Pedal Position: erratic or intermittent signal | |
| 5193 | 1632 | 31 | Engine Torque Limit Feature: condition exists | |
| 5248 | 1623 | 13 | Tachograph Output Shaft Speed: out of calibration | |
| 6563 | 976 | 2 | Auxiliary Intermediate (PTO) Speed Switch Validation: erratic or intermittent signal |
Battery, power supply and sensor supply 78 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 187 | 3510 | 4 | Sensor Supply 2 Circuit: circuit voltage low / shorted low | |
| 227 | 3510 | 3 | Sensor Supply 2 Circuit: circuit voltage high / shorted high | |
| 238 | 3511 | 4 | Sensor Supply 3 Circuit: circuit voltage low / shorted low | |
| 239 | 3511 | 3 | Sensor Supply 3 Circuit: circuit voltage high / shorted high | |
| 351 | 3597 | 12 | Injector Power Supply: bad device or component | |
| 352 | 3509 | 4 | Sensor Supply 1 Circuit: circuit voltage low / shorted low | |
| 386 | 3509 | 3 | Sensor Supply 1 Circuit: circuit voltage high / shorted high | |
| 434 | 627 | 2 | Power Lost without Ignition Off: erratic or intermittent signal | |
| 441 | 168 | 18 | Battery 1 Voltage: reading below normal (moderately severe) | |
| 442 | 168 | 16 | Battery 1 Voltage: reading above normal (moderately severe) | |
| 487 | 626 | 18 | Start Enable Device 1 Canister Empty (Ether Injection): reading below normal (moderately severe) | |
| 515 | 3514 | 3 | Sensor Supply 6 Circuit: circuit voltage high / shorted high | |
| 516 | 3514 | 4 | Sensor Supply 6 Circuit: circuit voltage low / shorted low | |
| 584 | 677 | 3 | Starter Relay Driver Circuit: circuit voltage high / shorted high | |
| 585 | 677 | 4 | Starter Relay Driver Circuit: circuit voltage low / shorted low | |
| 596 | 167 | 16 | Electrical Charging System Voltage High: reading above normal (moderately severe) | |
| 597 | 167 | 18 | Electrical Charging System Voltage Low: reading below normal (moderately severe) | |
| 598 | 167 | 1 | Electrical Charging System Voltage Low: reading below normal (most severe) | |
| 621 | 1137 | 18 | Low #1 LB Cylinder Power: reading below normal (moderately severe) | |
| 622 | 1138 | 18 | Low #2 LB Cylinder Power: reading below normal (moderately severe) | |
| 623 | 1139 | 18 | Low #3 LB Cylinder Power: reading below normal (moderately severe) | |
| 624 | 1140 | 18 | Low #4 LB Cylinder Power: reading below normal (moderately severe) | |
| 625 | 1141 | 18 | Low #5 LB Cylinder Power: reading below normal (moderately severe) | |
| 626 | 1142 | 18 | Low #6 LB Cylinder Power: reading below normal (moderately severe) | |
| 627 | 1143 | 18 | Low #7 LB Cylinder Power: reading below normal (moderately severe) | |
| 628 | 1144 | 18 | Low #8 LB Cylinder Power: reading below normal (moderately severe) | |
| 631 | 1143 | (45) | Low #1 RB Cylinder Power: fault | |
| 632 | 1144 | (45) | Low #2 RB Cylinder Power: fault | |
| 633 | 1145 | (45) | Low #3 RB Cylinder Power: fault | |
| 634 | 1146 | (45) | Low #4 RB Cylinder Power: fault | |
| 635 | 1147 | (45) | Low #5 RB Cylinder Power: fault | |
| 636 | 1148 | (45) | Low #6 RB Cylinder Power: fault | |
| 637 | 1151 | 18 | Low #7 RB Cylinder Power: reading below normal (moderately severe) | |
| 638 | 1152 | 18 | Low #8 RB Cylinder Power: reading below normal (moderately severe) | |
| 661 | 1137 | 16 | High #1 LB Cylinder Power: reading above normal (moderately severe) | |
| 662 | 1138 | 16 | High #2 LB Cylinder Power: reading above normal (moderately severe) | |
| 663 | 1139 | 16 | High #3 LB Cylinder Power: reading above normal (moderately severe) | |
| 664 | 1140 | 16 | High #4 LB Cylinder Power: reading above normal (moderately severe) | |
| 665 | 1141 | 16 | High #5 LB Cylinder Power: reading above normal (moderately severe) | |
| 666 | 1142 | 16 | High #6 LB Cylinder Power: reading above normal (moderately severe) | |
| 667 | 1143 | 16 | High #7 LB Cylinder Power: reading above normal (moderately severe) | |
| 668 | 1144 | 16 | High #8 LB Cylinder Power: reading above normal (moderately severe) | |
| 711 | 1143 | (45) | High #1 RB Cylinder Power: fault | |
| 712 | 1144 | (45) | High #2 RB Cylinder Power: fault | |
| 713 | 1145 | (45) | High #3 RB Cylinder Power: fault | |
| 714 | 1146 | (45) | High #4 RB Cylinder Power: fault | |
| 715 | 1147 | (45) | High #5 RB Cylinder Power: fault | |
| 716 | 1148 | (45) | High #6 RB Cylinder Power: fault | |
| 717 | 1150 | 0 | High #7 RB Cylinder Power: reading above normal (most severe) | |
| 718 | 1151 | 0 | High #8 RB Cylinder Power: reading above normal (most severe) | |
| 951 | 166 | 2 | Cylinder Power Imbalance between cylinders: erratic or intermittent signal | |
| 1117 | 3597 | 2 | Power Supply Lost With Ignition On: erratic or intermittent signal | |
| 1695 | 3513 | 3 | Sensor Supply 5: circuit voltage high / shorted high | |
| 1696 | 3513 | 4 | Sensor Supply 5: circuit voltage low / shorted low | |
| 1776 | 2634 | 3 | Power Relay Driver Circuit: circuit voltage high / shorted high | |
| 1777 | 2634 | 4 | Power Relay Driver Circuit: circuit voltage low / shorted low | |
| 1938 | 3597 | 18 | ECU Power Output Supply Voltage 1: reading below normal (moderately severe) | |
| 1939 | 3597 | 3 | ECU Power Output Supply Voltage 1: circuit voltage high / shorted high | |
| 1941 | 3597 | 4 | ECU Power Output Supply Voltage 1: circuit voltage low / shorted low | |
| 2185 | 3512 | 3 | Sensor Supply 4 Circuit: circuit voltage high / shorted high | |
| 2186 | 3512 | 4 | Sensor Supply 4 Circuit: circuit voltage low / shorted low | |
| 2263 | 1800 | 16 | Battery Temperature: reading above normal (moderately severe) | |
| 2264 | 1800 | 18 | Battery Temperature: reading below normal (moderately severe) | |
| 2738 | 626 | 3 | Start Enable Device 1 Circuit (Ether Injection): circuit voltage high / shorted high | |
| 2739 | 626 | 4 | Start Enable Device 1Circuit (Ether Injection): circuit voltage low / shorted low | |
| 3419 | 5125 | 3 | Sensor Supply 7 Circuit: circuit voltage high / shorted high | |
| 3421 | 5125 | 4 | Sensor Supply 7 Circuit: circuit voltage low / shorted low | |
| 3724 | 168 | 17 | Battery 1 Voltage: reading below normal (least severe) | |
| 3737 | 1675 | 31 | Engine Starter Mode Overcrank Protection: condition exists | |
| 4951 | 6655 | 3 | Maintain ECU Power Lamp: circuit voltage high / shorted high | |
| 4952 | 6655 | 4 | Maintain ECU Power Lamp: circuit voltage low / shorted low | |
| 4953 | 3353 | 3 | Alternator 1 Status: circuit voltage high / shorted high | |
| 4954 | 3353 | 4 | Alternator 1 Status: circuit voltage low / shorted low | |
| 6256 | 168 | 15 | Battery 1 Voltage: reading above normal (least severe) | |
| 6257 | 168 | 17 | Battery 1 Voltage: reading below normal (least severe) | |
| 6499 | 3597 | 17 | ECU Power Output Supply Voltage 1: reading below normal (least severe) | |
| 6511 | 6655 | 3 | Maintain ECU Power Lamp: circuit voltage high / shorted high | |
| 6512 | 6655 | 4 | Maintain ECU Power Lamp: circuit voltage low / shorted low |
ECM, network and data link 48 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 111 | 629 | 12 | ECM Critical Internal Failure: bad device or component | |
| 184 | 609 | 2 | ECM Identification Input State Error: erratic or intermittent signal | |
| 185 | 639 | 2 | ECM Network Communication Error: erratic or intermittent signal | |
| 211 | 1484 | 31 | Additional OEM/Vehicle Diagnostic Codes have been logged. Check other ECM's for DTC's.: condition exists | |
| 269 | 1195 | 2 | Antitheft Password Valid Indicator: erratic or intermittent signal | |
| 285 | 639 | 9 | SAE J1939 Multiplexing PGN Timeout Error: abnormal update rate | |
| 286 | 639 | 13 | SAE J1939 Multiplexing Configuration Error: out of calibration | |
| 288 | 974 | 19 | SAE J1939 Multiplexing Remote Accelerator Pedal or Lever Position Sensor System: network data error | |
| 291 | 625 | 9 | Proprietary Datalink Error (OEM/Vehicle Datalink): abnormal update rate | |
| 299 | 1384 | 31 | Engine Shutdown Commanded by J1939: condition exists | |
| 319 | 251 | 2 | Real Time Clock: erratic or intermittent signal | |
| 341 | 630 | 2 | ECM: erratic or intermittent signal | |
| 342 | 630 | 13 | ECM: out of calibration | |
| 343 | 629 | 12 | ECM Warning Internal Hardware Failure: bad device or component | |
| 346 | 630 | 12 | ECM: bad device or component | |
| 414 | 608 | 9 | Data Communication error over the J1587 data link Circuit: abnormal update rate | |
| 426 | 639 | 2 | J1939 Network #1: erratic or intermittent signal | |
| 427 | 639 | 9 | SAE J1939 Datalink: abnormal update rate | |
| 697 | 1136 | 3 | Engine ECU Temperature Sensor Circuit: circuit voltage high / shorted high | |
| 698 | 1136 | 4 | Engine ECU Temperature Sensor Circuit: circuit voltage low / shorted low | |
| 699 | 1136 | 2 | Engine ECU Temperature: erratic or intermittent signal | |
| 1256 | 1563 | 2 | Control Module Identification Input State Error: erratic or intermittent signal | |
| 1257 | 1563 | 2 | Control Module Identification Input State Error: erratic or intermittent signal | |
| 1515 | 91 | 19 | SAE J1939 Multiplexed Accelerator Pedal or Lever Sensor System: network data error | |
| 2661 | 629 | 31 | At Least One Unacknowledged Most Severe Fault: condition exists | |
| 2662 | 629 | 31 | At Least One Unacknowledged Moderately Severe Fault: condition exists | |
| 3213 | 1623 | 19 | Tachograph Output Shaft Speed: network data error | |
| 3298 | 1194 | 13 | Anti-theft Encryption Seed: out of calibration | |
| 3329 | 1231 | 2 | J1939 Network #2: erratic or intermittent signal | |
| 3331 | 1235 | 2 | J1939 Network #3: erratic or intermittent signal | |
| 3368 | 4490 | 19 | Specific Humidity Sensor: network data error | |
| 3371 | 1172 | 19 | Turbocharger 1 Compressor Intake Temperature Sensor: network data error | |
| 3373 | 1176 | 19 | Turbocharger 1 Compressor Intake Pressure: network data error | |
| 3418 | 191 | 19 | Transmission Output Shaft Speed: network data error | |
| 3525 | 84 | 19 | Wheel-Based Vehicle Speed: network data error | |
| 3527 | 558 | 19 | Accelerator Pedal or Lever Idle Validation Switch: network data error | |
| 3532 | 171 | 19 | Ambient Air Temperature: network data error | |
| 3535 | 1213 | 9 | Malfunction Indicator Lamp: abnormal update rate | |
| 3556 | 1081 | 19 | Engine Wait to Start Lamp: network data error | |
| 3614 | 111 | 19 | Coolant Level Sensor: network data error | |
| 3697 | 630 | 12 | ECM Calibration Memory: bad device or component | |
| 4437 | 1668 | 2 | J1939 Network #4: erratic or intermittent signal | |
| 4517 | 237 | 13 | Vehicle Identification Number: out of calibration | |
| 4721 | 237 | 31 | Vehicle Identification Number: condition exists | |
| 4722 | 237 | 2 | Vehicle Identification Number: erratic or intermittent signal | |
| 5133 | 2006 | 9 | Source Address 6: abnormal update rate | |
| 5939 | 520968 | 9 | Machine Constrained Operation- Abnormal Update Rate. No Communication or an invalid data transfer rate has been detected on the J1939 data link between the ECM and the machine electronic control unit.: abnormal update rate | |
| 5941 | 520968 | 19 | Machine Constrained Operation- Received Network Data in Error. The received J1939 datalink message was not valid.: network data error |
Auxiliary inputs, outputs and generator controls 34 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 292 | 441 | 14 | Auxiliary Temperature Sensor Input 1: special instructions | |
| 293 | 441 | 3 | Auxiliary Temperature Sensor Input 1 Circuit: circuit voltage high / shorted high | |
| 294 | 441 | 4 | Auxiliary Temperature Sensor Input 1 Circuit: circuit voltage low / shorted low | |
| 296 | 1388 | 14 | Auxiliary Pressure Sensor Input 2: special instructions | |
| 297 | 1388 | 3 | Auxiliary Pressure Sensor Input 2 Circuit: circuit voltage high / shorted high | |
| 298 | 1388 | 4 | Auxiliary Pressure Sensor Input 2 Circuit: circuit voltage low / shorted low | |
| 338 | 1267 | 3 | Idle Shutdown Vehicle Accessories Relay Driver Circuit: circuit voltage high / shorted high | |
| 339 | 1267 | 4 | Idle Shutdown Vehicle Accessories Relay Driver Circuit: circuit voltage low / shorted low | |
| 385 | 620 | 3 | OEM Sensor Supply Voltage Circuit: circuit voltage high / shorted high | |
| 444 | 620 | 18 | OEM Sensor Supply Voltage Low: reading below normal (moderately severe) | |
| 524 | 113 | 2 | OEM Alternate Droop Switch Validation: erratic or intermittent signal | |
| 527 | 702 | 3 | Auxiliary Input/Output 2 Circuit: circuit voltage high / shorted high | |
| 528 | 93 | 2 | Auxiliary Alternate Torque Validation Switch: erratic or intermittent signal | |
| 529 | 703 | 3 | Auxiliary Input/Output 3 Circuit: circuit voltage high / shorted high | |
| 779 | 703 | 11 | Auxiliary Equipment Sensor Input # 3 (OEM Switch): root cause not known | |
| 1427 | 4185 | 31 | Overspeed Shutdown Relay Driver Diagnostic has detected an error: condition exists | |
| 1429 | 4187 | 31 | High Engine Temperature (HET) Shutdown Relay Driver Diagnostic has detected an error: condition exists | |
| 1432 | 4223 | 31 | Pre-High Engine Temperature Warning Relay Driver Diagnostic has detected an error: condition exists | |
| 1539 | 1387 | 3 | Auxiliary Pressure Sensor Input 1 Circuit: circuit voltage high / shorted high | |
| 1621 | 1387 | 4 | Auxiliary Pressure Sensor Input 1 Circuit: circuit voltage low / shorted low | |
| 2194 | 1387 | 11 | Auxiliary Equipment Sensor Input # 2 (OEM Pressure Sensor) Engine Protection: root cause not known | |
| 2195 | 703 | 14 | Auxiliary Equipment Sensor Input # 3 (OEM Switch) Engine Protection: special instructions | |
| 2557 | 697 | 3 | Auxiliary PWM Driver 1 Circuit: circuit voltage high / shorted high | |
| 2558 | 697 | 4 | Auxiliary PWM Driver 1 Circuit: circuit voltage low / shorted low | |
| 3694 | 4184 | 4 | Gain Adjust Potentiometer Circuit: circuit voltage low / shorted low | |
| 3695 | 4182 | 4 | Generator Output Frequency Adjust Potentiometer Circuit: circuit voltage low / shorted low | |
| 3696 | 4183 | 4 | Droop Adjust Potentiometer Circuit: circuit voltage low / shorted low | |
| 3765 | 442 | 3 | Auxiliary Temperature Sensor Input 2 Circuit: circuit voltage high / shorted high | |
| 3766 | 442 | 4 | Auxiliary Temperature Sensor Input 2 Circuit: circuit voltage low / shorted low | |
| 4724 | 702 | 5 | Auxiliary Input/Output 2 Circuit: circuit open / current low | |
| 4725 | 702 | 6 | Auxiliary Input/Output 2 Circuit: circuit grounded / current high | |
| 4734 | 701 | 14 | Auxiliary Input/Output 1: special instructions | |
| 6583 | 441 | 14 | Auxiliary Temperature Sensor Input 1: special instructions | |
| 6584 | 1388 | 14 | Auxiliary Pressure Sensor Input 2: special instructions |
Engine control and configuration 5 codes
| Code | SPN | FMI | Lamp | Meaning |
|---|---|---|---|---|
| 3715 | 188 | 16 | Engine Speed At Idle: reading above normal (moderately severe) | |
| 3716 | 188 | 18 | Engine Speed At Idle: reading below normal (moderately severe) | |
| 3838 | 2978 | 9 | Estimated Engine Parasitic Losses: abnormal update rate | |
| 5215 | 520791 | 2 | Engine Boost Curve Selection: erratic or intermittent signal | |
| 5291 | 520808 | 31 | Engine Emergency Shutdown Switch Actived: condition exists |
Cummins code questions
How do I read a Cummins fault code?
Cummins fault codes are numbers like 3714 or 1922. Each one maps to a J1939 SPN (the part or system) and FMI (the type of failure). Many dashes and scan tools show the SPN and FMI instead. Our lookup accepts either.
What is the difference between SPN, FMI and a Cummins fault code?
SPN (Suspect Parameter Number) is an industry-standard number for the component, like 3251 for DPF differential pressure. FMI (Failure Mode Identifier) is 0-31 and says what's wrong, like too high, too low, or shorted. Cummins assigns its own fault code number to each SPN and FMI combination.
What does a red stop lamp mean on a Cummins engine?
Stop the engine as soon as it is safe. Cummins uses the red lamp for faults that can damage the engine or are unsafe to keep running.
Do these codes apply to my Ram Cummins pickup?
Ram 2500 and 3500 trucks with the 6.7 Cummins mostly show standard OBD-II P-codes on a regular scan tool. The Cummins fault code numbers here are what Cummins diagnostic software (INSITE) shows, and what medium-duty and heavy-duty trucks and equipment display on the dash.

Diesel down in the Midlands?
We work on Cummins-powered pickups, vans and medium-duty trucks across Lexington, Columbia and the Midlands, on site at your yard or roadside.